All Isco brand portable samplers are built to withstand harsh environments and hard service.
Sequential Portable Samplers is available in multiple bottles.
Click the below button to view in detail.
Wide range of bottle configurations, plug-in flow and parameter monitoring - and Isco reliability
Advanced sampling capabilities in a smaller package
Full-size performance and flexibility
Fits where a full-size sampler can't
6712 Full-Size Portable Sampler
Wide range of bottle configurations, plug-in flow and parameter monitoring – and Isco reliability
The 6712 Portable Sampler features a vacuum-formed ABS plastic shell to withstand exposure and abuse. Its tapered design and trim 20-inch (50.8 cm) diameter result in easy manhole installation and removal. Large, comfortable handles make transporting safe and convenient - even when wearing gloves. The NEMA 4X, 6 (IP67) enclosure is submersible, watertight, and dust-tight. Plug-in 700 Series Modules and the SDI-12 interface make it easy to add flow and parameter monitoring to your 6712-based system.
Standard Features
Applications
Options and Accessories
|
Specifications
6712 Full-Size Portable Sampler |
|
Size (Diam x Ht): | 20 x 27.0 inches (68.6 x 50.7 cm) |
Weight: | Dry, Less Battery - 32 lbs (15 kg) |
Material: | Plastic with UV-resistant gel coat |
Power Requirements: | 12 VDC |
Pump |
|
Intake purge: | Adjustable air purge before and after each sample. |
Tubing life indicator: | Provides a warning to change pump tubing. |
Intake suction tubing: | Vinyl or Teflon®; 3/8 inch (1 cm) ID; 3 to 99 feet (1 to 30 m) Length |
Pump tubing life: | Typically 1,000,000 pump counts |
Maximum lift: | 28 feet (8.5 m) |
Repeatability: | Typical ±5 ml or ±5% of the average volume in a set |
Typical line velocity @ Head height: | 3.0 ft./s @ 3 ft; 2.9 ft./s @ 10 ft; 2.7 ft./s @ 15 ft. (0.91 m/s @ 0.9 m; 0.87 m/s @ 3.1 m; 0.83 m/s @ 4.6 m) |
Liquid presence detector: | Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights. |
Controller |
|
Weight: | 13 lbs. (5.9 kg) |
Size (HxWxD): | 10.3 x 12.5 x 10 inches (26 x 31.7 x 25.4 cm) |
Operational temperature: | 32° to 120°F (0° to 49°C) |
Enclosure rating: | NEMA 4X, 6 IP67 |
Program memory: | Non-volatile ROM |
Flow meter signal input: | 5 to 15 volt DC pulse or 25 millisecond isolated contact closure. |
Number of composite samples: | Programmable from 1 to 999 samples. |
Clock Accuracy: | 1 minute per month, typical, for real time clock |
Software |
|
Sample frequency: | 1 minute to 99 hours 59 minutes, in 1 minute increments. Non-uniform times in minutes or clock times 1 to 9,999 flow pulses |
Sampling modes: | Uniform time, non-uniform time, flow, event. (Flow mode is controlled by external flow meter pulses.) |
Programmable sample volumes: | 10 to 9,990 ml in 1 ml increments |
Sample retries: | If no sample is detected, up to 3 attempts; user selectable |
Rinse cycles: | Automatic rinsing of suction line up to 3 rinses for each sample collection |
Program storage: | 5 sampling programs |
Sampling Stop/Resume: | Up to 24 real time/date sample stop/resume commands |
Controller diagnostics: | Tests for RAM, ROM, pump display, and distributor |
6712C Compact Portable Sampler
Advanced sampling capabilities in a smaller package
The 6712C compact model gives you the world's most versatile sampler controller in a smaller-diameter package that fits in 18" and offset manholes. Large, comfortable handles make transporting safe and convenient - even when wearing gloves. The NEMA 4X, 6 (IP67) enclosure is submersible, watertight, and dust-tight. Plug-in 700 Series Modules and the SDI-12 interface make it easy to add flow and parameter monitoring to your 6712-based system. Standard Features
Applications
Options and Accessories
|
Specifications
6712C Compact Portable Sampler |
|
Size (Diam x Ht): | 17.7 x 27.6 inches (45.7 x 70.1 cm) |
Weight: | Dry, Less Battery - 31 lbs (14 kg) |
Material: | Plastic with UV-resistant gel coat |
Power Requirements: | 12 VDC |
Pump |
|
Intake purge: | Adjustable air purge before and after each sample. |
Tubing life indicator: | Provides a warning to change pump tubing. |
Intake suction tubing: | Vinyl or Teflon®; 3/8 inch (1 cm) ID; 3 to 99 feet (1 to 30 m) Length |
Pump tubing life: | Typically 1,000,000 pump counts |
Maximum lift: | 28 feet (8.5 m) |
Repeatability: | Typical ±5 ml or ±5% of the average volume in a set |
Typical line velocity @ Head height: | 3.0 ft./s @ 3 ft; 2.9 ft./s @ 10 ft; 2.7 ft./s @ 15 ft. (0.91 m/s @ 0.9 m; 0.87 m/s @ 3.1 m; 0.83 m/s @ 4.6 m) |
Liquid presence detector: | Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights. |
Controller |
|
Weight: | 13 lbs. (5.9 kg) |
Size (HxWxD): | 10.3 x 12.5 x 10 inches (26 x 31.7 x 25.4 cm) |
Operational temperature: | 32° to 120°F (0° to 49°C) |
Enclosure rating: | NEMA 4X, 6 IP67 |
Program memory: | Non-volatile ROM |
Flow meter signal input: | 5 to 15 volt DC pulse or 25 millisecond isolated contact closure. |
Number of composite samples: | Programmable from 1 to 999 samples. |
Clock Accuracy: | 1 minute per month, typical, for real time clock |
Software |
|
Sample frequency: | 1 minute to 99 hours 59 minutes, in 1 minute increments. Non-uniform times in minutes or clock times 1 to 9,999 flow pulses |
Sampling modes: | Uniform time, non-uniform time, flow, event. (Flow mode is controlled by external flow meter pulses.) |
Programmable sample volumes: | 10 to 9,990 ml in 1 ml increments |
Sample retries: | If no sample is detected, up to 3 attempts; user selectable |
Rinse cycles: | Automatic rinsing of suction line up to 3 rinses for each sample collection |
Program storage: | 5 sampling programs |
Sampling Stop/Resume: | Up to 24 real time/date sample stop/resume commands |
Controller diagnostics: | Tests for RAM, ROM, pump display, and distributor |
3700 Full-Size Portable Sampler
Full-size performance and flexibility
The full-featured 3700 Sampler collects sequential or composite samples based on time, flow rate, or storm conditions. It's a great choice if you don't need the sophisticated parameter monitoring and logging capabilities of our 6700 Series. Standard Features
Applications
Options and Accessories
|
Specifications
3700 Full-size Portable Sampler |
|
Size (Diam x Ht): | 19 x 25 inches (50.5 x 64 cm) |
Weight: | Dry, less battery - 37 lbs (16.8 kg) |
Material: | ABS Plastic |
Power required: | 12 VDC |
Pump |
|
Intake purge: | Adjustable air purge before and after each sample. |
Tubing life indicator: | Provides a warning to change pump tubing. |
Pump tubing life: | Recommended 500,000 pump counts |
Intake suction tubing: | Vinyl or Teflon®; 3/8 inch (1 cm) or 1/4 inch (0.6cm) ID; 3 to 99 feet (1 to 30 m) Length |
Maximum lift: | 26 ft. (7.9 m) |
Repeatability: | ±10 ml typical |
Typical line velocity @ Head height: | 2.5 ft./s @ 3 ft; 2.5 ft./s @ 10 ft; 1.9 ft./s @ 15 ft. (0.76 m/s @ 0.9 m; 0.76 m/s @ 3.1 m; 0.58 m/s @ 4.6 m) |
Liquid presence detector: | Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights. |
Controller |
|
Weight: | 11 lbs (5 kg) |
Size (HxWxD): | 10 x 12.5 x 10 inches (25 x 32 x 25 cm) |
Operational temperature: | 32° to 120°F (0° to 49°C) |
Enclosure rating: | NEMA 4X, 6 IP67 |
Program memory: | Non-volatile ROM |
Flow meter signal input: | 5 to 15 volt DC pulse or 25 millisecond isolated contact closure. |
Interface port: | 8 pin connector; data output at 2400 baud in ASCII. RS-232 format with handshake. |
Clock accuracy: | 1 minute per month, typical, for real time clock |
Software |
|
Sample frequency: | 1 minute to 99 hours 59 minutes, in 1 minute increments. Non-uniform times in minutes or clock times 1 to 9,999 flow pulses |
Sample pacing: | Uniform time, non-uniform time, flow, flow paced/time switched, STORM (time and flow paced sampling during sample collection.) Flow pacing is controlled by external flow pulses. |
Multiplexing: | Samples per bottle (1 to 50 with 1000 ml bottles; 1 to 17 with 350 ml bottles), bottles per sample (1 to 24), multiple bottle compositing. |
Sample volumes: | Programmable from 10 to 9,990 ml in 1 ml increments |
Sample retries: | If no sample is detected, up to 3 attempts; user selectable |
Rinse cycles: | Automatic rinsing of suction line up to 3 rinses for each sample collection |
Program storage: | 3 sampling programs |
Programming modes: | Basic, extended and STORM |
Sampling stop/resume: | Up to 24 real time/date sample stop/resume commands. |
Controller diagnostics: | Tests for RAM, ROM, pump display, and distributor |
3700C Compact Porrtable Sampler
Fits where a full-size sampler can't
Smaller and lighter than our full size 3700 portable, the 3700C uses the same controller. The 3700C will easily pass through an 18-inch diameter or offset manhole. Standard Features
Applications
Options and Accessories
|
Specifications
3700C Compact Portable Sampler |
|
Size (Diam x Ht): | 17 x 27 inches (45 x 70.5 cm) |
Weight: | Dry, less battery - 25 lbs (11.3 kg) |
Material: | ABS Plastic |
Power required: | 12 VDC |
Pump |
|
Intake purge: | Adjustable air purge before and after each sample. |
Tubing life indicator: | Provides a warning to change pump tubing. |
Pump tubing life: | Recommended 500,000 pump counts |
Intake suction tubing: | Vinyl or Teflon®; 3/8 inch (1 cm) or 1/4 inch (0.6cm) ID; 3 to 99 feet (1 to 30 m) Length |
Maximum lift: | 26 ft. (7.9 m) |
Repeatability: | ±10 ml typical |
Typical line velocity @ Head height: | 2.5 ft./s @ 3 ft; 2.5 ft./s @ 10 ft; 1.9 ft./s @ 15 ft. (0.76 m/s @ 0.9 m; 0.76 m/s @ 3.1 m; 0.58 m/s @ 4.6 m) |
Liquid presence detector: | Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights. |
Controller |
|
Weight: | 11 lbs (5 kg) |
Size (HxWxD): | 10 x 12.5 x 10 inches (25 x 32 x 25 cm) |
Operational temperature: | 32° to 120°F (0° to 49°C) |
Enclosure rating: | NEMA 4X, 6 IP67 |
Program memory: | Non-volatile ROM |
Flow meter signal input: | 5 to 15 volt DC pulse or 25 millisecond isolated contact closure. |
Interface port: | 8 pin connector; data output at 2400 baud in ASCII. RS-232 format with handshake. |
Clock accuracy: | 1 minute per month, typical, for real time clock |
Software |
|
Sample frequency: | 1 minute to 99 hours 59 minutes, in 1 minute increments. Non-uniform times in minutes or clock times 1 to 9,999 flow pulses |
Sample pacing: | Uniform time, non-uniform time, flow, flow paced/time switched, STORM (time and flow paced sampling during sample collection.) Flow pacing is controlled by external flow pulses. |
Multiplexing: | Samples per bottle (1 to 50 with 1000 ml bottles; 1 to 17 with 350 ml bottles), bottles per sample (1 to 24), multiple bottle compositing. |
Sample volumes: | Programmable from 10 to 9,990 ml in 1 ml increments |
Sample retries: | If no sample is detected, up to 3 attempts; user selectable |
Rinse cycles: | Automatic rinsing of suction line up to 3 rinses for each sample collection |
Program storage: | 3 sampling programs |
Programming modes: | Basic, extended and STORM |
Sampling stop/resume: | Up to 24 real time/date sample stop/resume commands. |
Controller diagnostics: | Tests for RAM, ROM, pump display, and distributor |