The Signature® flow meter is designed for open channel flow monitoring applications. It supports flow measurement technologies including ultrasonic, bubbler, submerged ultrasonic area velocity, and non-contacting laser Doppler area velocity. The meter can calculate flow using standard open channel level-to-flow conversions, as well as user defined equations or level to flow data points, depending on the application need.
With multiple smart interface options and multi-parameter logging (such as pH), the Signature flow meter provides a common platform for control action, reporting, and communication.
Flexible, configurable flow meter for permanent discharge compliance monitoring
Flexible, configurable flow meter for permanent discharge compliance monitoring
The Signature flow meter is designed for open channel flow monitoring applications. It supports flow measurement technologies including bubbler, non-contact laser area velocity, submerged Doppler ultrasonic area velocity, and ultrasonic. The meter can calculate flow using standard open channel level-to-flow and area velocity conversions, as well as user-defined equations, level to area data points, or level to flow data points, depending on the application need. Standard Features
Applications
Options and Accessories
|
Specifications
Signature® Flow Meter |
|
Size (HxWxD): | 8.88 x 12.22 x 8.22 in. (with mounting bracket), 16.74 x 13.58 x 10.48 in (with stand) |
Materials: | PPO Polyphenylene Oxide |
Enclosure (self-certified): | NEMA 4X/IP66 |
Power Required: | 100 to 240 VAC, 50/60 Hz |
Cable Entry: | Standard- ¾" NPT conduit, optional- ¾" NPT cord grips |
Flow Measurement Technologies: | Ultrasonic (TIENet 310), Bubbler (TIENet 330), Area Velocity (TIENet 350, 360) |
Inputs: | Two SDI-12, two MODBUS ASCII/RTU, pH Measurement (TIENet 301), Analog In (TIENet 307), Rain In |
Setup: | Front Panel Keypad, Flowlink Software - with serial USB, remote cellular, or Ethernet |
Flow Conversions: | Area Velocity, Weir, Flume, British Flume, Metering Insert, Manning Formula, Equation, Level to Flow Data Points, Level to Area Data Points |
Data Storage: | Non-volatile flash; retains stored data during program updates. Interval- 15 or 30 seconds; 1, 2, 5, 15, or 30 minutes; or 1, 2, 4, 12, or 24 hours. Capacity- 8 MB (180 days with 5 parameters logged at 1 minute intervals, reports once per day). |
Data Retrieval: | USB drive, Flowlink Software - with serial USB, remote cellular, or Ethernet |
Outputs: | MODBUS ASCII/RTU, Analog (TIENet 308), Contact Output (TIENet 304), SMS Alarm |
Sampler Interface: | TIENet 306 |
TIENet® 301 pH/Temperature Device |
|
Weight (w/o probe): | 3.5 lb w/ 10 m cable, 7.5 lb w/ 23 m cable |
Ambient Operating Temperature: | -20 to 50 °C (-4 to 122 °F) |
pH Measurement Range: | 0 - 14 pH units |
Temperature Compensation: | Performed by the 301 device |
pH Accuracy: | ±0.1 pH units (new probe, freshly calibrated w/in range) |
Probe Dimensions: | 1.12" X 6" long, 3/4 NPT; Cable 25 ft |
Probe Body Material: | 316SST |
pH Electrode Junction: | Double porous |
Temperature Measurement Range: | 0 to 80 °C (32 to 176 °F) |
TIENet® Model 304 Contact Output |
|
Type: | NO or NC, Galvanically isolated |
Output rating: | 30 volts, 1 Ampere |
Operating Temperature: | -20 to 70 °C (-4 to 158 °F) |
TIENet® Model 306 Sampler Interface |
|
Function: | Flow pacing, enabling based on triggered event. Time and bottle information sent to Signature Flow Meter |
Powered By: | Signature Flow Meter |
Operating Temperature: | -20 to 50 °C (-4 to 122 °F) |
Storage Temperature: | -40 to 60 °C (-40 to 140 °F) |
Pulse Width: | 50 ms |
Pulse Output: | 5 volts |
Sampler Connection: | Standard 6 pin connector for Isco 6712, Avalanche, Glacier, GLS, and 3700 samplers. For other options, contact factory |
TIENet® Model 307 Analog Input |
|
Power source in active mode: | 17-29 volts |
Isolation: | Galvanically isolated |
Input Impedance: | 400 ohm |
Operating Temperature: | -20 to 70 °C (-4 to 158 °F) |
TIENet® Model 308 Analog Output |
|
Output: | 4-20 mA |
Isolation: | Monolithic |
Maximum Load: | 900 ohm |
Outputs per Card: | Two |
TIENet® Model 310 Ultrasonic Level Sensor |
|
Measurement Range: | 0.3 to 3.3 m (1 to 11 ft) |
Accuracy at 72 °F (22 °C): | ±0.006 m (0.02 ft) at less than or equal to 1 ft level change, ±0.009 m (0.03 ft) at greater than 1 ft level change |
Temperature Coefficient (w/ in compensated range): | ±0.0002 x Distance (m) x Temperature Deviation from 22 °C. ±0.00011 x Distance (ft) x Temperature Deviation from 72 °F. |
Beam Angle: | 10° (5° from center line) |
Frequency: | 50 kHz |
Size: | 9.1 cm diameter X 10.2 cm tall (3.63"x 4") |
Cable Length: | 10 or 23 m (32.8 or 75.5 ft) |
Weight: | 1.8 kg (4 lbs) |
Body Material: | PVDF |
Temperature Range: | -30° to 60 °C, -22° to 140 °F (Operating & Storage) |
Certifications: | Group 2, Category 1G (zone 0), T4, Class I, Div 1, Groups C & D, T4 (pending) |
TIENet® 330 Bubbler Module |
|
Level Measurement Range: | 0.003 to 3.05m (0.01 to 10 ft) |
Level Measurement Accuracy: | +0.002m @ 22 °C (0.007 ft @ 72 °F) |
Operating and Storage Temperature: | -18° to 60 °C (0 to 140 °F) |
Temperature Compensation Range: | 0° to 60 °C (32° to 140 °F) |
Temperature Coefficient (w/in compensated range): | ±0.0003 x Level (m) x Temperature Deviation from 22 °C. ±0.00017 x Level (ft) x Temperature Deviation from 72 °F. |
TIENet® Model 350 Area Velocity Sensor |
|
Probe Dimensions: | 1.9 x 3.3 x 15.2 cm (0.75 x 1.3 x 6.0 in) |
Materials: | Sensor- epoxy, chlorinated PC, SST; Cable- UV-Rated PVC |
Temperature Range: | 0 to 70 °C (32 to 158 °F) |
Velocity Measurement Range: | -1.5 to 6.1 m/s (-5 to 20 ft/s) |
Velocity Measurement: | Bi-Directional |
Velocity Accuracy: | ±0.03 m/s (±0.1 ft/s) from -5 to 5 ft/s; ±2% of reading from 5 to 20 ft/s, Uniform velocity profile |
Minimum Depth: | 25 mm (0.08 ft) |
Frequency: | 500 kHz |
Level Measurement Range: | 0.01 to 3.05 m (0.033 to 10 ft) |
Level Accuracy: | ± 0.10% Full Scale |
Maximum Allowable Depth: | 10.5 m (34 ft) |
Typical Long-Term Stability: | ±0.007 m/yr (±0.023 ft/yr) |
TIENet® Model 360 LaserFlow Velocity Sensor |
|
Sensor Dimensions: | 38.01 x 26.21 x 56.7 cm, 14.96 x 10.3 x 22.32 in |
Weight: | 8.7 kg (19.2 lbs) |
Materials: | Conductive Carbon Filled ABS, SST, Conductive Kynar, Anodized Aluminum, UV-Rated PVC |
Temperature Range: | Operating 0 to 60 °C (32 to 140 °F). Storage -40 to 60 °C (-40 to 140 °F) |
Cable Lengths: | 5, 10, or 15 m (16.4, 32.8, or 49.2 ft) |
Enclosure: | IP68 |
Certifications: | CE EN61326; FDA CDRH 21CFR1040; IEC 60825-1 |
Power Required: | 8 to 26 VDC Input voltage, 12 VDC Nominal |
Flow Accuracy: | ±5% of Reading. (Typical, under normal flow conditions) |
Velocity Measurement Range: | -4.6 m/s to 4.6 m/s (-15 ft/s to 15 ft/s) |
Direction: | Bi-Directional |
Velocity Accuracy: | ±0.5% of reading ±0.03 m/s (0.1 ft/s) |
Minimum Velocity: | 0.25 m/s (0.8 ft/s) |
Level Measurement Range: | 0 to 3 m (0 to 10 ft) from measurement point |
Level Accuracy @ 22 °C (72 °F): | ±0.006 m (0.02 ft) at less than or equal to 1 ft level change; ±0.012 m (0.04 ft) at greater than 1 ft level change |
Temperature Coefficient within compensated range: | ± 0.0002 x D (m) per degree C; ± 0.00011 x D (ft) per degree F (Where D = Distance from transducer to liquid surface) |
Beam Angle: | 10° (5° from center line) |
Ultrasonic Signal: |
50 KHz |