Isco developed the first refrigerated sampler designed for use outdoors without an enclosure, and continues to set the standards for weather and corrosion resistance.
Compliance Monitoring Refrigerated Samplers
The all-new Isco 5800 Refrigerated Sampler is purpose-built to survive outdoors for wastewater compliance monitoring. 'Built to last' with the features and performance you need for wastewater compliance monitoring, Isco 5800 Refrigerated Sampler is the answer to the rigorous demands of wastewater monitoring. Click below for more details
"FR" Samplers for Outdoor/Corrosive Environments
Our 6712FR refrigerator gives you field-proven, trouble-free sample preservation and dependability in harsh environments, along with the most advanced sampler controller available. Fiberglass-bodied refrigerator resists corrosion, weather, and temperature extremes, the advanced 6712FR Fiberglass Refrigerated Sampler is our top-of-the-line FR refrigerator. Click below for more details.
The answer to the rigorous demands of wastewater monitoring
The 5800 Refrigerated Sampler is Isco's answer to the rigorous demands of water monitoring. With user-friendly controls and workplace-savvy features, the 5800 is the only choice for stationary sampling in both municipal and industrial wastewater applications. Standard Features
Applications
Options and Accessories
|
Specifications
Isco 5800 Refrigerated Sampler |
|
Size (HxWxD): | 52 x 28 x 33 in (132 x 72 x 84 cm) |
Weight (empty): | 184 lb (83.5 kg) |
Refrigerator body: | Linear low-density polyethylene (LLDPE) |
Power requirements: | 115VAC, 60 Hz, or 230 VAC, 50 Hz (specify) |
Operational temperature: | -20 to 120 °F (-29 to 49°C) The display response time may be longer at temperatures below 0 °F. |
Pump |
|
Intake suction tubing length: | 3 to 99 feet (1 to 30 m) |
Intake suction tubing material: | Vinyl or FEP-lined PE. |
Intake suction tubing inside diameter: | 3/8 inch (9 mm) |
Pump tubing life: | Typically 1,000,000 pump counts. |
Maximum suction lift: | 28 feet (8.5 m) |
Typical repeatability: | ±5 ml or ±5% of the average volume in a set, whichever is greater, at lifts up to 25 ft. |
Typical accuracy at lifts up to 25 ft: | ±10 ml or ±10% of programmed value, whichever is greater. |
Typical line velocity at head height: | 3 ft. (0.9 m) = 3.0 ft./s (0.91 m/s); 10 ft. (3.1 m) = 2.9 ft./s (0.87 m/s); 15 ft. (4.6 m) = 2.7 ft./s (0.83 m/s) |
Liquid presence detector: | Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights. |
Controller |
|
Enclosure rating: | NEMA 4X, 6 (IP67) |
Program memory: | Non-volatile ROM. |
Flow meter signal inputs: | 5 to 15 volt DC pulse or 25 ms isolated contact closure for Isco flow meters. 4-20 mA input for non-Isco flow meters. |
Digital alarms: | 4 programmable outputs; 5V, 100 mA |
Number of composite samples: | Programmable from 1 to 999 samples. |
Software |
|
Sample frequency: | 1 minute to 99 hours 59 minutes, in 1-minute increments. 1 to 9,999 flow pulses. |
Sampling modes: | Constant time - constant volume, Constant time - variable volume, Variable time - constant volume (Flow modes are controlled by external flow meter signal). |
Programmable sample volumes: | 10 to 9,990 ml in 1 ml increments. |
Sample retries: | If no sample is detected, up to 3 attempts; user selectable. |
Rinse cycles: | Automatic rinsing of suction line up to 3 rinses for each sample collection. |
Controller diagnostics: | Tests for RAM, ROM, pump, display, and electrical components. |
6712FR Fiberglass Refrigerated Sampler
Advanced 6712 sampling in our top-of-the-line FR refrigerator
The 6712FR is a sequential or composite refrigerated sampler designed to withstand the harshest indoor or outdoor environments. It features our unequalled "FR" model corrosion-proof refrigerator cabinet molded from polyester resin fiberglass and supported by a stainless steel frame. A UV-resistant gel coat provides a smooth, non-porous finish for added protection and easy cleaning. Thick, foamed-in-place insulation helps keep samples preserved at the EPA-recommended 39°F (4°C). An automatically controlled, built-in heater ensures that samples won't freeze. Standard Features
Applications
Options and Accessories
|
Specifications
Sampler |
|
Size (HxWxD): | 49.3 x 26 x 26 inches (125 cm x 66 x 66 cm) |
Weight (Dry): | 160 lbs (73 kg) |
Refrigerator Body: | Fiberglass reinforced plastic with UV-resistant gel coat |
Power Required: | 120 VAC, 60 Hz; OR 240 VAC, 50 Hz (specify) |
Pump |
|
Intake purge: | Adjustable air purge before and after each sample. |
Tubing life indicator: | Provides a warning to change pump tubing. |
Intake suction tubing: | Vinyl or Teflon®; 3/8 inch (1 cm) ID; 3 to 99 feet (1 to 30 m) Length |
Pump tubing life: | Typically 1,000,000 pump counts |
Maximum lift: | 28 feet (8.5 m) |
Repeatability: | Typical ±5 ml or ±5% of the average volume in a set |
Typical line velocity @ Head height: | 3.0 ft./s @ 3 ft; 2.9 ft./s @ 10 ft; 2.7 ft./s @ 15 ft. (0.91 m/s @ 0.9 m; 0.87 m/s @ 3.1 m; 0.83 m/s @ 4.6 m) |
Liquid presence detector: | Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights. |
Controller |
|
Weight: | 13 lbs. (5.9 kg) |
Size (HxWxD): | 10.3 x 12.5 x 10 inches (26 x 31.7 x 25.4 cm) |
Operational temperature: | 32° to 120°F (0° to 49°C) |
Enclosure rating: | NEMA 4X, 6 IP67 |
Program memory: | Non-volatile ROM |
Flow meter signal input: | 5 to 15 volt DC pulse or 25 millisecond isolated contact closure. |
Number of composite samples: | Programmable from 1 to 999 samples. |
Clock Accuracy: | 1 minute per month, typical, for real time clock |
Software |
|
Sample frequency: | 1 minute to 99 hours 59 minutes, in 1 minute increments. Non-uniform times in minutes or clock times 1 to 9,999 flow pulses |
Sampling modes: | Uniform time, non-uniform time, flow, event. (Flow mode is controlled by external flow meter pulses.) |
Programmable sample volumes: | 10 to 9,990 ml in 1 ml increments |
Sample retries: | If no sample is detected, up to 3 attempts; user selectable |
Rinse cycles: | Automatic rinsing of suction line up to 3 rinses for each sample collection |
Program storage: | 5 sampling programs |
Sampling Stop/Resume: | Up to 24 real time/date sample stop/resume commands |
Controller diagnostics: | Tests for RAM, ROM, pump display, and distributor |