Refrigerated Samplers

Isco developed the first refrigerated sampler designed for use outdoors without an enclosure, and continues to set the standards for weather and corrosion resistance. 
 

Compliance Monitoring Refrigerated Samplers

The all-new Isco 5800 Refrigerated Sampler is purpose-built to survive outdoors for wastewater compliance monitoring. 'Built to last' with the features and performance you need for wastewater compliance monitoring, Isco 5800 Refrigerated Sampler is the answer to the rigorous demands of wastewater monitoring. Click below for more details

 

"FR" Samplers for Outdoor/Corrosive Environments

Our 6712FR refrigerator gives you field-proven, trouble-free sample preservation and dependability in harsh environments, along with the most advanced sampler controller available. Fiberglass-bodied refrigerator resists corrosion, weather, and temperature extremes, the advanced 6712FR Fiberglass Refrigerated Sampler is our top-of-the-line FR refrigerator. Click below for more details.


 

5800 Refrigerated Sampler

The answer to the rigorous demands of wastewater monitoring 

 

The 5800 Refrigerated Sampler is Isco's answer to the rigorous demands of water monitoring. With user-friendly controls and workplace-savvy features, the 5800 is the only choice for stationary sampling in both municipal and industrial wastewater applications. 

Along with easy control and on-site programmability, it also has a unique slide-out bottle rack that eliminates awkward stooping and bending when retrieving sample containers. 

The controller actively regulates and displays the sample compartment temperature, and logs a 24-hour summary to confirm proper sample cooling. Not only can you download the temperature record with a basic utility program such as Tera Term, you can also view this information on the unit display. 

Isco-tough - and environmentally friendly, too 
The 5800 Sampler follows the Isco standard for weather and corrosion resistance. The tough, double-wall LLDPE cabinet shrugs off exposure to weather and harsh environments. It is filled from top to bottom with insulation for efficient temperature control for keeping samples cool in hot, humid conditions and has heaters to keep the samples from freezing in cold conditions. 

Heat-treated polyester powder coating protects the refrigeration system, ensuring long life and reliability in corrosive treatment plant conditions. 

Advanced delivery system 
The 5800 Sampler uses Isco's proven peristaltic pump to deliver samples at the EPA-recommended line velocity of at least 2 ft/s (0.6 m/s), even at head heights up to 25 feet (7.6 m). 

Sample volume accuracy is assured by the pump revolution counter and Isco's liquid detection system. Pump tubing replacement is simple and fast without requiring tools. A safety interlock disables the pump during tube replacement.

Standard Features

  • Composite or sequential sampling 
  • Operating range of -20 to 120°F (-29 to 49°C) - without additional heaters 
  • Four digital alarm outputs 
  • 4-20 mA and DC pulse flow meter input 
  • Powerful compressor delivers energy-efficient, high-performance cooling 
  • Four stored programs 
  • Lifting handles for easy installation 
  • Display will flash to indicate an error 
    o Efficient, high-performance cooling

Applications

  • Wastewater Treatment Plants 
  • Industrial Pretreatment 
  • Influent and effluent sampling

Options and Accessories

  • Flow pacing from an external flow meter 
  • 24, 4, 2, and single bottle configurations in glass or plastic 
  • 24 or single bottle disposable ProPak configurations 
  • Optional Chinese-language display
 

 

Specifications

Isco 5800 Refrigerated Sampler

Size (HxWxD): 52 x 28 x 33 in (132 x 72 x 84 cm)
Weight (empty): 184 lb (83.5 kg)
Refrigerator body: Linear low-density polyethylene (LLDPE)
Power requirements: 115VAC, 60 Hz, or 230 VAC, 50 Hz (specify)
Operational temperature: -20 to 120 °F (-29 to 49°C) The display response time may be longer at temperatures below 0 °F.

Pump

Intake suction tubing length: 3 to 99 feet (1 to 30 m)
Intake suction tubing material: Vinyl or FEP-lined PE.
Intake suction tubing inside diameter: 3/8 inch (9 mm)
Pump tubing life: Typically 1,000,000 pump counts.
Maximum suction lift: 28 feet (8.5 m)
Typical repeatability: ±5 ml or ±5% of the average volume in a set, whichever is greater, at lifts up to 25 ft.
Typical accuracy at lifts up to 25 ft: ±10 ml or ±10% of programmed value, whichever is greater.
Typical line velocity at head height: 3 ft. (0.9 m) = 3.0 ft./s (0.91 m/s); 10 ft. (3.1 m) = 2.9 ft./s (0.87 m/s); 15 ft. (4.6 m) = 2.7 ft./s (0.83 m/s)
Liquid presence detector: Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights.

Controller

Enclosure rating: NEMA 4X, 6 (IP67)
Program memory: Non-volatile ROM.
Flow meter signal inputs: 5 to 15 volt DC pulse or 25 ms isolated contact closure for Isco flow meters. 4-20 mA input for non-Isco flow meters.
Digital alarms: 4 programmable outputs; 5V, 100 mA
Number of composite samples: Programmable from 1 to 999 samples.

Software

Sample frequency: 1 minute to 99 hours 59 minutes, in 1-minute increments. 1 to 9,999 flow pulses.
Sampling modes: Constant time - constant volume, Constant time - variable volume, Variable time - constant volume (Flow modes are controlled by external flow meter signal).
Programmable sample volumes: 10 to 9,990 ml in 1 ml increments.
Sample retries: If no sample is detected, up to 3 attempts; user selectable.
Rinse cycles: Automatic rinsing of suction line up to 3 rinses for each sample collection.
Controller diagnostics: Tests for RAM, ROM, pump, display, and electrical components.

Back To Top ^


 

6712FR Fiberglass Refrigerated Sampler

Advanced 6712 sampling in our top-of-the-line FR refrigerator 

 

The 6712FR is a sequential or composite refrigerated sampler designed to withstand the harshest indoor or outdoor environments. It features our unequalled "FR" model corrosion-proof refrigerator cabinet molded from polyester resin fiberglass and supported by a stainless steel frame. A UV-resistant gel coat provides a smooth, non-porous finish for added protection and easy cleaning. Thick, foamed-in-place insulation helps keep samples preserved at the EPA-recommended 39°F (4°C). An automatically controlled, built-in heater ensures that samples won't freeze. 

The heart of the 6712FR is Isco's advanced 6712 Controller. It allows you to select different programming modes to assure the most suitable routine for your application. Programming is fast and simple, with on-line help just a key stroke away. 

In Standard Programming Mode, the controller walks you through the sampling sequence step-by-step, allowing you to choose all parameters specific to your application. Extended Programming Mode lets you enter more complex programs including “smart sampling” event notification, triggered on any combination of up to 16 inputs.

Standard Features

  • SDI-12 interface provides “plug and play” connection with compatible measuring devices - including multi-parameter sondes from leading manufacturers. 
  • Standard 512KB of memory gives you great flexibility for logging environmental data. 
  • Corrosion-proof refrigerator cabinet is molded from polyester resin fiberglass and UV-resistant gel coat provides a smooth, non-porous finish for added protection and easy cleaning 
  • Heavy-duty stainless steel frame and cabinet. 
  • Automatic built-in heater ensures that samples won't freeze, even when ambient temperatures drop to -20°F (-29°C). 
  • Durable powder-coated epoxy, phenolic paint, or polyester tubing, protects refrigeration components. 
  • Sample delivery at the EPA-recommended velocity of 2 ft/sec., even at head heights of 26 feet. 
  • Pump revolution counter and patented liquid detection sensor ensure accurate sample volumes - and tells you when tubing should be replaced.

Applications

  • wastewater effluent 
  • stormwater monitoring 
  • CSO monitoring 
  • permit compliance 
  • pretreatment compliance

Options and Accessories

  • Composite sampling bottle configurations 
  • Sequential sampling bottle configurations 
  • ProPak disposable sample bags 
  • Suction lines and strainers 
  • 674 Rain Gauge 
  • 700 Series Modules for flow and parameter measurement 
  • Telephone Modem 
  • 581 RTD data retrieval device 
  • Cellphone based data retrieval, dial-out alarms, and remote control 
  • Wireless radio data retrieval with 2102 module 
  • Multi-parameter sonde (pH, conductivity, temperature, DO) 
  • Flowlink® Software 
  • Optional temperature sensor - provides precise log of sample compartment temperature for automatic documentation
 

 

Specifications

Sampler

Size (HxWxD): 49.3 x 26 x 26 inches (125 cm x 66 x 66 cm)
Weight (Dry): 160 lbs (73 kg)
Refrigerator Body: Fiberglass reinforced plastic with UV-resistant gel coat
Power Required: 120 VAC, 60 Hz; OR 240 VAC, 50 Hz (specify)

Pump

Intake purge: Adjustable air purge before and after each sample.
Tubing life indicator: Provides a warning to change pump tubing.
Intake suction tubing: Vinyl or Teflon®; 3/8 inch (1 cm) ID; 3 to 99 feet (1 to 30 m) Length
Pump tubing life: Typically 1,000,000 pump counts
Maximum lift: 28 feet (8.5 m)
Repeatability: Typical ±5 ml or ±5% of the average volume in a set
Typical line velocity @ Head height: 3.0 ft./s @ 3 ft; 2.9 ft./s @ 10 ft; 2.7 ft./s @ 15 ft. (0.91 m/s @ 0.9 m; 0.87 m/s @ 3.1 m; 0.83 m/s @ 4.6 m)
Liquid presence detector: Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights.

Controller

Weight: 13 lbs. (5.9 kg)
Size (HxWxD): 10.3 x 12.5 x 10 inches (26 x 31.7 x 25.4 cm)
Operational temperature: 32° to 120°F (0° to 49°C)
Enclosure rating: NEMA 4X, 6 IP67
Program memory: Non-volatile ROM
Flow meter signal input: 5 to 15 volt DC pulse or 25 millisecond isolated contact closure.
Number of composite samples: Programmable from 1 to 999 samples.
Clock Accuracy: 1 minute per month, typical, for real time clock

Software

Sample frequency: 1 minute to 99 hours 59 minutes, in 1 minute increments. Non-uniform times in minutes or clock times 1 to 9,999 flow pulses
Sampling modes: Uniform time, non-uniform time, flow, event. (Flow mode is controlled by external flow meter pulses.)
Programmable sample volumes: 10 to 9,990 ml in 1 ml increments
Sample retries: If no sample is detected, up to 3 attempts; user selectable
Rinse cycles: Automatic rinsing of suction line up to 3 rinses for each sample collection
Program storage: 5 sampling programs
Sampling Stop/Resume: Up to 24 real time/date sample stop/resume commands
Controller diagnostics: Tests for RAM, ROM, pump display, and distributor

Back To Top ^