The Avalanche® and Glacier® Samplers combine the small size, light weight, and mobility of a portable with an exclusive new active temperature control system. The revolutionary design gives you the best of all worlds: easy transport, quick setup, and accurate sample preservation – without reliance on ice or utility power! An optional Mobility Kit with aluminum frame and pneumatic tires lets you wheel these unique samplers even over rough terrain to remote sampling sites.
Advanced sampling and data logging with transportable, dual-power cooling
It’s a brand new kind of sampler!
Avalanche® Multi-bottle, Multi-function Sampler
Advanced sampling and data logging with transportable, dual-power cooling
The Avalanche® Sampler is based on the industry-leading 6712 controller. Avalanche provides the advanced control, data logging, and communication features of the 6712, combined with on-the-go cooling from either AC power or a 12-volt deep cycle battery. Bottle configurations include 5 gallon and 2.5 gallon composite as well as 4 x 1 gallon and 14 x 950 ml sequential. Standard Features
Applications
Options and Accessories
|
Specifications
Avalanche® Multi-Bottle Transportable Refrigerated Sampler |
|
Size (HxWxL): | 30.5 x 14 x 24 inches (78 x 36 x 60 cm) |
Weight: | Dry, less battery - 76 lbs (35 kg) |
Power Requirements: | 12 VDC, 6 Amps (supplied by external battery), OR 87 to 264 VAC, 47 to 63 Hz, 2 Amps |
Cooling: | CFC-free refrigeration system maintains sample temperature at 3° C±1°C at ambient temperature of 0°C to 40°C. |
Operational Temperatures: | 0°C to 50°C |
Pump |
|
Intake purge: | Adjustable air purge before and after each sample. |
Tubing life indicator: | Provides a message to change pump tubing. |
Intake suction tubing: | Length 3 to 99 ft. (1 to 30 m), Vinyl or Teflon® lined, ID 0.375 in. |
Pump tubing life: | Typically 1,000,000 pump counts |
Typical repeatability: | ±5 ml or ±5% of the average volume in a set |
Maximum lift: | 28 ft. (8.5 m) |
Typical line velocity @ Head height: | 3.0 ft./s @ 3 ft; 2.9 ft./s @ 10 ft; 12.7 ft./s @ 15 ft. (0.91 m/s @ 0.9 m; 0.87 m/s @ 3.1 m; 0.83 m/s @ 4.6 m) |
Sample presence detector: | Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights. |
Controller |
|
Weight: | 13 lbs. (5.9 kg) |
Size: | 10 x 12.5 x 10 inches (26 x 32.x 25 cm) |
Operational temperature: | 32° to 120°F (0° to 49°C) |
Enclosure rating: | NEMA 4X, 6 (IP67) |
Program memory: | Non-volatile ROM |
Flow meter signal input: | 5 to 15 volt DC pulse or 25 millisecond isolated contact closure |
External trigger: | Initiates sample collection and cooling from contact closure signal |
Number of programmable composite samples: | 1 to 999 samples |
Clock Accuracy: | 1 minute per month, typical, for real time clock |
Software |
|
Sample frequency selection: | 1 minute to 99 hours 59 minutes, in 1 minute increments Non-uniform times in minutes or clock times 1 to 9,999 flow pulses |
Sampling modes: | Uniform time, non-uniform time, flow, event. (Flow mode is controlled by a flow module or external flow meter pulses.) |
Programmable sample volumes: | 10 to 9,990 ml in 1 ml increments |
Sample Retries: | If no sample is detected, up to 3 attempts; user selectable |
Rinse Cycles: | Automatic rinsing of suction line up to 3 rinses for each sample collection |
Program storage: | Five sampling programs |
Sampling stop/resume: | Up to 24 real time/date sample stop/resume commands |
Controller diagnostics: |
Tests for RAM, ROM, pump, and display |
It’s a brand new kind of sampler!
The Glacier® Sampler combines the small size, light weight, and mobility of a portable with an exclusive new active temperature control system. Its revolutionary design gives you the best of all worlds: easy transport, quick setup, and accurate sample preservation – without reliance on ice or utility power! An optional Mobility Kit with aluminum frame and pneumatic tires lets you wheel Glacier even over rough terrain to remote sampling sites Standard Features
Applications
Options and Accessories
|
Specifications
Glacier® Transportable Refrigerated Sampler |
|
Size: | 25 x 15 x 24 inches (63 x 38 x 60 cm) |
Weight: | Dry, less battery - 60 lbs (28 kg) |
Bottle configurations: | 1 – 10 Liter PE or Glass; 1 – 20 Liter PE; 1 – 9 Liter ProPak composite sample container with disposable liners |
Power Requirements: | 12 VDC (Supplied by external battery), or 120/240 VAC power with included line cord. |
Cooling: | CFC-free refrigeration system maintains sample temperature at 3°C±1°C at ambient temperature of 0°C to 40°C. |
Pump |
|
Intake purge: | Purge before and after each sample. |
Tubing life indicator: | Provides a message to change pump tubing. |
Intake suction tubing: | Length 3 to 99 ft. (1 to 30 m), Vinyl or PTFE lined, ID 0.375 in. or 0.250 in |
Pump tubing life: | 2,000 samples |
Typical repeatability: | ±10 ml |
Maximum lift: | 26 ft. (7.9 m) |
Typical line velocity @ Head height: | 2.9 ft./s @ 3 ft; 2.5 ft./s @ 10 ft; 1.9 ft./s @ 15 ft. (0.88 m/s @ 0.9 m; 0.76 m/s @ 3.1 m; 0.58 m/s @ 4.6 m) |
Sample presence detector: | Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights. |
Controller |
|
Weight: | 8 lbs. (3.6 kg) |
Size: | 10 x 12.5 x 10 inches (26 x 32.x 25 cm) |
Operational temperature: | 32° to 120°F (0° to 49°C) |
Enclosure rating: | NEMA 4X, 6 (IP67) |
Program memory: | Non-volatile ROM |
Flow meter signal input: | 5 to 15 volt DC pulse or 25 millisecond isolated contact closure for flow-paced sampling. |
External trigger: | Initiates sample collection and cooling from contact closure signal |
Number of samples to shutoff: | 999 samples maximum with 5 gallon (19 liter) bottle. |
Clock Accuracy: | 1 minute per month, typical, for real time clock |
Software |
|
Sample frequency selection: | 1 minute to 9,999 minutes, in 1 minute increments. 1 to 9,999 flow pulses |
Sampling modes: | Time or flow, event. (Flow mode is controlled by external flow meter pulses.) |
Programmable sample volumes: | 10 to 9,990 ml in 1 ml increments |
Program storage: | One program running, one stored |
Controller diagnostics: | Tests for RAM, ROM, pump, and display |