Before LaserFlow, non-contact sensors only measured surface velocity. Now, this non-contact sensor penetrates the water with laser technology to measure velocity at multiple subsurface points.
Advanced laser Doppler technology for non-contacting area velocity flow measurement
LaserFlow™ Non-contact Velocity Sensor
Advanced laser Doppler technology for non-contacting area velocity flow measurement
The LaserFlow™ velocity sensor remotely measures flow in open channels with non-contact Laser Doppler Velocity technology and non-contact Ultrasonic Level technology. The sensor uses advanced technology to measure velocity with a laser beam at single or multiple points below the surface of the wastewater stream. Standard Features
Applications
Options and Accessories
|
Specifications
Primary Measurement - TIENet® 360 LaserFlow™ Sensor |
|
Size (HxWxD): | 38.01 x 26.21 x 56.7 cm (14.96 x 10.3 x 22.32 in) |
Weight: | 8.7 kg (19.2 lbs) |
Materials: | Conductive Carbon Filled ABS, SST, Conductive Kynar®, Anodized Aluminum, UV-Rated PVC |
Cable Lengths: | 10 or 23 m (32.8 or 75.5 ft) |
Enclosure: | IP68 |
Certifications: | CE EN61326; FDA CDRH, 21CFR1040; IEC 60825-1 |
Laser Class: | Class 3R |
Operating Temperature Range: | -20 to 60 °C (-4 to 140 °F) |
Storage Temperature Range: | -40 to 60 °C (-40 to 140 °F) |
Power: | Required Input voltage 8 to 26 VDC, 12VDC Nominal |
Flow Accuracy: | ±4% of reading under normal conditions |
LaserFlow Velocity Measurement |
|
Technology: | Non-Contact, Subsurface Laser Doppler Velocity (patent pending) |
Measurement Range: | -4.6 m/s to 4.6 m/s (-15 ft/s to 15 ft/s) |
Maximum Distance from Liquid Surface to Bottom of Sensor: | 3 m (10 ft) |
Direction: | Selectable Bidirectional flow measurement. Requires turbidity > 20 NTU and distance from liquid surface to bottom of sensor < 0.61 m (2 ft) |
Accuracy: | ±0.5% of reading ±0.03 m/s (0.1 ft/s) |
Minimum Velocity: | 0.15 m/s (0.5 ft/s) |
LaserFlow Level Measurement |
|
Technology: | Non-Contact Ultrasonic |
Measurement Range: | 0 to 3 m (0 to 10 ft) from measurement point |
Accuracy @ 22 °C (72 °F): | ±0.006 m (0.02 ft) at less than or equal to 1 ft level change; ±0.012 m (0.04 ft) at greater than or equal to 1 ft level change |
Temperature Coefficient within compensated range: | ± 0.0002 x D (m) per degree C; ± 0.00011 x D (ft) per degree F (Where D = Distance from transducer to liquid surface) |
Beam Angle: | 10° (5° from center line) |
Ultrasonic Signal: | 50 KHz |
Deadband: | Zero deadband from bottom of LaserFlow sensor. Deadband for remote TIENet® 310 ultrasonic level sensor varies, depending on the type of mounting hardware. |
Optional Secondary Measurement with TIENet® 350 AV sensor |
|
Probe Size (HxWxL): | 19 x 33 x 152 mm (0.75 x 1.3 x 6.0 in) |
Sensor Material: | Epoxy, chlorinated CPVC, SST |
Cable Material: | UV-Rated PVC |
Certifications: | CE EN61326 |
Temperature Range: | 0 to 70 °C (32 to 158 °F) |
Optional TIENet® 350 AV Sensor Velocity Measurement |
|
Technology: | Submerged Continuous Wave Doppler Ultrasonic |
Measurement Range: | -1.5 to 6.1 m/s (-5 to 20 ft/s) |
Velocity Measurement: | Bidirectional |
Accuracy: | ±0.03 m/s (±0.1 ft/s) from -5 to 5 ft/s; ±2% of reading from 5 to 20 ft/s, uniform velocity profile |
Minimum Depth: | 25 mm (0.08 ft) |
Frequency: | 500 kHz |
Optional TIENet® 350 AV Sensor Level Measurement |
|
Technology: | Submerged Differential Linear Pressure Transducer |
Measurement Range: | 0.01 to 3.05 m (0.033 to 10 ft) |
Accuracy: | ± 0.10% of full scale |
Maximum Depth: | 10.5 m (34 ft) |
Stability: | ±0.007 m/yr (±0.023 ft/yr) |