Now you can collect samples and measure flow or water quality parameters with one advanced sampler. Simply plug one of the 700 Series Modules into your 6700 Series Sampler (including 6712 and Avalanche models) to add the capability you need. These environmentally-sealed modules can be interchanged in the field, and can be added to your Isco system at any time. The 700 Series Modules bring “Plug and Play” to the world of water quality monitoring!
Add pH and temperature sensing to your 6712 or Avalanche Sampler
Submerged probe accuracy unaffected by wind, steam, foam, turbulence or air temperature change
Bubbler level sensing provides the most accurate measurement.
Area Velocity - no weir or flume needed! Handles submerged, surcharged, and reverse flow.
Adds intelligence to your analog signal
Add pH and temperature sensing to your 6712 or Avalanche Sampler
Plug the 701 module into your 6712 Sampler, and place the streamlined stainless steel sensor in the flow stream for accurate monitoring and logging of pH and temperature. Additionally, you can trigger the sampler to collect samples only when a specific limit is exceeded. This can be done for the entire sampling program, or you can collect separate samples of independent volumes when the parameters exceed your programmed limits. Standard Features
Applications
Options and Accessories
|
Specifications
701 Module |
|
Size (HxWxD): | 4.9 x 5.7 x 2.0 in (12.4 x 14.5 x 5.1 cm) |
Weight: | 1.5 lbs (0.7 kg) |
Material: | Polystyrene |
Enclosure: | NEMA 4X, 6 IP67 |
Power: | 9 to 14V DC (provided by 6700 Series Sampler) |
Program Memory: | Non-volatile, programmable flash; can be updated via interrogator port on 6700 Series Sampler using a PC |
Operating Temperature: | 32° to 120°F (0° to 49°C) |
Storage Temperature: | 0° to 140°F (-18° to 60°C) |
Probe |
|
Description: | Submersible vertical or horizontal mounting probe with combination type porous Teflon® liquid double junction pH electrode to resist fouling and coating. Steam sterilized glass hemi-bulb for long term stability. Built-in amplifier and integral exposed temperature sensor. |
Size: | 6" (15.24 cm) long x 3/4" (1.9 cm) NPT |
Body material: | 316 Stainless Steel |
pH range: | 0 to 14 pH |
pH accuracy: | ±0.1% over full range |
Temperature accuracy: | ±1.8°F (±1°C) |
Temperature range: | 32° to 176°F (0° to 80°C). Continuous exposure to temperatures above 140°F (60°C) may shorten probe life. |
Probe cable length: |
25 ft. (8 m) standard length; longer lengths available. |
720 Submerged Probe Flow Module
Submerged probe accuracy unaffected by wind, steam, foam, turbulence or air temperature change
The probe on the Isco 720 is mounted at the bottom of the channel, and uses a differential pressure transducer to measure the level of the flow stream. The 6712 Sampler then converts this depth measurement into flow rate. The probe's venting system automatically compensates for changes in atmospheric pressure to maintain accuracy. The 720 provides accurate measurement at sites where wind, steam, foam, turbulence or air temperature fluctuations exist. The probe is suitable for small channels, and accurately senses pressure even when covered with silt and sand. Isco mounting rings make it easy to install the probe in round pipes, manhole inverts, and other open channels. And with the Isco Street Level Installation Tool, you can install your monitoring system from ground level, eliminating the costs and hazards of entering manholes. Most flumes are also available with an integral recess for mounting an Isco Submerged Probe.
Standard Features
Applications
Options and Accessories
|
Specifications
720 Module |
|
Size (HxWxD): | 4.9 x 5.7 x 2.0 in (12.4 x 14.5 x 5.1 cm) |
Weight: | 1.1 lbs (0.5 kg) |
Material: | Polystyrene |
Enclosure: | NEMA 4X, 6 IP67 |
Power: | 9 to 14V DC (provided by 6700 Series Sampler) |
Program Memory: | Non-volatile, programmable flash; can be updated via interrogator port on 6700 Series Sampler using a PC |
Operating Temperature: | 32° to 120°F (0° to 49°C) |
Storage Temperature: | 0° to 140°F (-18° to 60°C) |
Submerged probe |
|
Dimensions: | 9.5 x 0.875 in (24.1 x 2.2 cm) |
Cable: | Standard range probe - 25 ft x 0.3 in (7.6 m x 0.8 cm); Extended range probe - 50 ft x 0.3 in (15.2 m x 0.8 cm) |
Level Measurement Method: | Submerged pressure transducer mounted in the flow stream |
Transducer Type: | Differential linear integrated circuit pressure transducer |
Operating Temperature: | 32° to 160°F (0° to 71°C) |
Compensated Temperature: | 32° to 100°F (0° to 38°C) |
Materials: | Type 316 stainless steel, chlorinated polyvinyl chloride (CPVC); PVC Cable |
Level Measurement Range: | 0.1 to 10 ft (0.03 to 3.05 m) |
Maximum Allowable Level: | 20 ft (6.1 m) |
Level Measurement Accuracy (at 25°C (77°F) - Max error (±) for indicated level range) |
|
0.1 to 5.0 ft (0.03 to 1.52 m): | ±0.01 ft (±0.003 m) |
0.1 to 7.0 ft (0.03 to 2.13 m): | ±0.03 ft (±0.009 m) |
0.1 to 10 ft (0.03 to 3.05 m): | ±0.10 ft (±0.03 m) |
Temperature Coefficient (Max error per degree of temperature change over compensated range) |
|
0.1 to 4.0 ft (0.03 to1.22m): | ±0.005ft/°F (±0.0027m/°C) |
4.0 to 10 ft (1.22 to 3.05m): | ±0.007ft/°F (±0.0038m/°C) |
Bubbler level sensing provides the most accurate measurement.
Isco 730 Bubbler Flow Modules use an internal air compressor to force a metered amount of air through a bubble line submerged in the flow channel. By measuring the pressure needed to force air bubbles out of the line, the water level is accurately determined. The 6712 Sampler then converts this level into flow rate. The 730 provides accurate measurement in a variety of conditions. It is suitable for small channels, and is not affected by wind, steam, foam or turbulence. And, because only the bubble tube contacts the flow, corrosive chemicals are not a problem. Automatic bubble line purging prevents clogging. The 730 also resists damage by lightning and debris, making it ideal for stormwater applications. Automatic Drift Compensation makes Isco bubbler flow meters the most accurate level measurement technology. In standby applications such as stormwater runoff monitoring, Automatic Drift Compensation also allows the 730 to maintain calibration for extended periods in standby applications such as stormwater runoff monitoring. Standard Features
Applications
Options and Accessories
|
Specifications
730 Module |
|
Size (HxWxD): | 4.9 x 5.7 x 2.0 in (12.4 x 14.5 x 5.1 cm) |
Weight: | 1.1 lbs (0.5 kg) |
Material: | Polystyrene |
Enclosure: | NEMA 4X, 6 IP67 |
Power: | 9 to 14V DC (provided by 6700 Series Sampler) |
Program Memory: | Non-volatile, programmable flash; can be updated via interrogator port on 6700 Series Sampler using a PC |
Operating Temperature: | 32° to 120°F (0° to 49°C) |
Storage Temperature: | 0° to 140°F (-18° to 60°C) |
Bubbler |
|
Range: | 0.1 to 10 ft (0.03 to 3.05 m) |
Level Measurement Accuracy (Non-linearity, repeatability, and hysteresis at 25°C (77°F). Max error (±) for indicated level range. |
|
0.1 to 5.0 ft (0.03 to 1.52 m): | ±0.005 ft (±0.002 m) |
0.1 to 7.0 ft (0.03 to 2.13 m): | ±0.01 ft (±0.003 m) |
0.1 to 10 ft (0.03 to 3.05 m): | ±0.035 ft (±0.011 m) |
Temperature Coefficient (Maximum error (±) per degree of temperature change over compensated range) |
|
For level in feet: | ±0.0003 x level x temperature change from 72°F |
For level in meters: | ±0.0009 x level x temperature change from 22°C |
Automatic Drift Correction: | After a 5 minute warm-up period, zero level is corrected to ±0.002 ft. (±0.0006 m) at intervals between 2 and 15 minutes |
Long-Term Level Calibration Change: | Typically 0.5% of reading per year |
Ambient Operating Temperature Range: | 0° to 140°F (-18° to 60°C) |
Compensated Temperature Range: | 32° to 140°F (0° to 60°C) |
Area Velocity - no weir or flume needed! Handles submerged, surcharged, and reverse flow.
The sensor on the 750 module uses patented Doppler technology to directly measure average velocity in the flow stream. An integral pressure transducer measures liquid depth to determine flow area. The 6712 sampler then calculates flow rate by multiplying the area of the flow stream by its average velocity. Standard Features
Applications
Options and Accessories
|
Specifications
750 Area Velocity Module |
|
Size (HxWxD): | 4.9 x 5.7 x 2.0 in (12.4 x 14.5 x 5.1 cm) |
Weight: | 0.9 lbs (0.4 kg) |
Material: | Polystyrene |
Enclosure: | NEMA 4X, 6 IP67 |
Power: | 9 to 14V DC (provided by 6700 Series Sampler) |
Program Memory: | Non-volatile, programmable flash; can be field updated through sampler |
Operating Temperature: | 32° to 120°F (0° to 49°C) |
Storage Temperature: | 0° to 140°F (-18° to 60°C) |
Level-to-Area Conversions |
|
Channel shapes: | Round, U-shaped, rectangular, trapezoidal |
Data points: | Four sets of 50 level-area points |
Level-to-Flow Rate Conversions |
|
Weirs: | V-notch, rectangular, Cipolletti |
Flumes: | Parshall, Palmer-Bowlus, Leopold-Lagco,Trapezoidal, H, HS, HL |
Manning Formula: | Round, U-channel, rectangular, trapezoidal |
Data Points: | Four sets of 50 level-flow rate points |
Equation: | Two-term polynomial |
Area Velocity Sensor – Standard and Extended Range |
|
Size (LxWxH): | 6.6 x 1.6 x 1.2 inches (16.8 x 4.1 x 3.0 cm) |
Weight, incl. cable: | 2.1 lbs (0.96 kg) for standard range probe with 25 foot cable; 3.9 lbs (1.8 kg) for extended range probe with 50 ft cable. |
Materials: | Polybutadiene-based polyurethane, stainless steel; PVC and CPVC cable |
Operating Temperature Range: | 32° to 160°F (0° to 71°C) |
Compensated Temperature Range: | 32° to 100°F (0° to 38°C) |
Velocity Measurement |
|
Method: | Doppler Ultrasonic, 500 kHz |
Velocity range: | -5 to +20 ft/s (-1.5 to 6.1 m/s) |
Minimum depth: | 0.25 ft (75mm), typical |
Level Measurement |
|
Method: | Submerged pressure transducer |
Standard range probe: | Measurement range 0.05 to 10 ft (0.015 to 3.05 m); max level 20 ft (6.1 m) |
Extended range probe: | Measurement range 0.05 to 30 ft (0.015 to 9.1 m); max level 40 ft (12.2 m) |
Level Accuracy - Standard Range Probe, for indicated level range. Includes non-linearity, repeatability, and hysteresis at 25°C (77°F) |
|
0.033 to 5.0 ft (0.01 to 1.52m): | ±0.008 ft/ft (±0.008 m/m) |
>5.0 ft (>1.52 m): | ±0.012 ft/ft (±0.012 m/m) |
Level Accuracy - Extended Range Probe, for indicated level range. Includes non-linearity, repeatability, and hysteresis at 25°C (77°F) |
|
0.05 to 15ft (0.015 to 4.57m): | ±0.03 ft (±0.009 m) |
0.05 to 21ft (0.015 to 6.4m): | ±0.09 ft (±0.027 m) |
0.05 to 30ft (0.015 to 9.14m): | ±0.3 ft (±0.09 m) |
Area Velocity Sensor – Low Profile |
|
Size (LxWxH): | 6 x 1.3 x 0.75 inches (15.2 x 3.3 x 1.9 cm) |
Weight, incl. cable: | 2.1 lbs (0.96 kg) |
Materials: | Epoxy, CPVC, stainless steel; PVC and CPVC cable |
Operating Temperature Range: | 32° to 122°F (0° to 50°C) |
Cable length: | 25 ft (8m) standard. Up to 75 ft (22.8 m) with optional extension. Up to 1000 ft (300 m) with optional Quick Disconnect Box. |
Velocity Measurement |
|
Method: | Doppler Ultrasonic, 500 kHz |
Velocity range: | -5 to +20 ft/s (-1.5 to 6.1 m/s) |
Minimum depth: | 0.08 ft (25mm), typical |
Level Measurement |
|
Method: | Submerged pressure transducer |
Range: | 0.033 to 10 ft (0.01 to 3.05 m); max allowable level 20 ft (6.1 m) |
Level Accuracy: | Depths from 0.033 to 5.0 ft (0.01 to 1.52m): ±0.008 ft/ft (±0.008 m/m); Depth >5.0 ft (>1.52 m): ±0.012 ft/ft (±0.012 m/m). Accuracy per foot of change from calibrated depth @ 77°F (25°C). Includes non-linearity and hysteresis. |
Adds intelligence to your analog signal
The 780 Smart 4-20 Module gives your Isco 6700 Series Sampler the capability to interpret analog data from other equipment that you already own. For example, if you have flow meters that output a 4-20 mA signal, the 780 Module allows you to use that flow signal to pace your 6700 or 6712 sampler. The sampler with 780 module also converts the signal into digital information that can be displayed in real time and stored for future retrieval and analysis using Flowlink® Software. Standard Features
Applications
|
Specifications
Size (HxWxD): | 4.9 x 5.7 x 2.0 in. (12.4 x 14.5 x 5.1 cm) |
Weight: | 1.1 lbs. (0.5 kg) |
Material: | Polystyrene |
Enclosure: | NEMA 4X, 6 IP67 |
Power: | provided by 6700 Series Sampler |
Operating Temperature: | 32° to 120°F (0° to 49°C) |
Storage Temperature: | 0° to 140°F (-18° to 60°C) |
Data interval: | Programmable through the sampler at 1, 2, 5, 10, 15, or 30 minutes |
Accuracy: | ±0.5% |
Resolution: | ±0.1% |