4200 Series Flow Meters

 

The 4200 Series offers a choice of battery-powered, portable operation or AC power. Housed in rugged, NEMA 4 enclosures, the 4200s can store weeks of data in their large, versatile memory. They're fully compatible with our Flowlink Software, and also have a built-in printer for on-site reports. A choice of four measurement technologies lets you match the meter to your site conditions. Options include modems with dial-out alarm as well as rain gauges and water quality monitoring. 

     Ultrasonic level measurement - non-contacting sensor means no scheduled maintenance.

     Submerged probe accuracy unaffected by wind, steam, foam, turbulence or air temperature change.

     Bubbler level sensing provides the most accurate measurement.

     Area Velocity - no weir or flume needed! Handles submerged, surcharged, and reverse flow.


 

 4210 Flow Meter

Ultrasonic level measurement - non-contacting sensor means no scheduled maintenance. 

The 4210 Ultrasonic Flow Meter provides non-contact sensing of the flow over a weir or in a flume. The ultrasonic sensor is mounted above the flow stream, and transmits a sound pulse that is reflected by the surface of the flow. The elapsed time between sending a pulse and receiving an echo determines the level in the channel. Automatic compensation for air temperature ensures measurement accuracy. 

Because its sensor does not contact the liquid, the 4210 provides long-term dependability with no scheduled maintenance. The Isco 4210 is not affected by chemicals or high concentrations of grease, suspended solids or silt in the flow. 

You can retrieve stored data on-site with a laptop PC or an Isco 581 Rapid Transfer Device, or remotely via telephone using an optional modem. Isco Flowlink Software produces a variety of informative graphs and reports from stored data.

Standard Features

  • Built-in flow conversions for most applications, including Manning formula, data points, or equation for special situations.
  • Two-line x 80-character backlit LCD. 
  • Built-in dot matrix printer gives you an accurate, on-site printout 
  • Internal memory stores over 2 months of flow, rainfall, parameter, and sample data at 15 minute intervals. 
  • Automatic gain adjustment in response to echo strength - maximizes performance in the presence of steam, foam, and turbulence. 
  • Variable Blanking Distance eliminates false echo problems caused by obstructions such as manhole rungs. 
  • Interfacing for Sampler activation, connection to multiparameter water quality sonde, alarm outputs

Applications

  • Portable and fixed-site flow measurement with weirs and flumes 
  • Pretreatment Compliance 
  • Stormwater Runoff Monitoring 
  • Permit Enforcement 
  • Sewer Flow Monitoring 
  • Combined Sewer Overflow Studies 
  • Wastewater Treatment Plant Operations 
  • Inflow and Infiltration Studies 
  • River and Stream Gauging

Options and Accessories

  • Optional telephone modem - provides remote data retrieval, voice messaging, and dial-out alarm conditions 
  • Analog Outputs - up to 3 isolated internal 4-20 mA outputs 
  • Non-resettable totalizer 
  • 674 Rain Gauge 
  • 581 RTD data retrieval device downloads up to 20 meters 
  • 201 pH module adds pH and temperature measurement/logging 
  • YSI 600 Multi-Parameter Water Quality Monitor 
  • Suspension equipment (to hang flowmeter in manhole)
 

 

Specifications

Size (H x W x D): 17.0 x 11.5 x 10.5 in. (43 x 29 x 26.7 cm) (without power source)
Weight: 17.3 lbs (7.8 kg) (without power source)
Material: High-impact molded polystyrene structural foam
Enclosure: NEMA 4X (iP65)
Power: 12 to 14V DC, 24 mA average at 12.5V DC

Typical Battery Life (printer set at 1 in/hr, 1 minute level reading interval)

934 NiCad Battery: 7 to 8 days
946 Lead-Acid Battery: 10 to 12 days
948 Lead-Acid Battery: 2 to 2½ months
Program Memory: Non-volatile, programmable flash. Updateable without opening enclosure.
Display: Backlit LCD, 2-line, 80-character (5.5 mm high x 3.2 mm wide)

Level-to-Flow Rate Conversions

Weirs: V-notch, rectangular with and without end contractions, Cipolletti
Flumes: Parshall, Palmer-Bowlus, Leopold-Lagco,Trapezoidal, H, HS, HL
Manning Formula: Round, U-channel, rectangular, trapezoidal Data Points Four sets of 50 level-flow rate points Equation Two-term polynomial

Totalizers

LCD: 9-digit, floating decimal point, resettable
Mechanical (optional): 7-digit, non-resettable

Inputs and outputs

Rain Gauge Input: Contact closure, normally open. Resolution 0.01 or 0.004 in ( 0.25 or 0.1 mm)
Parameter Inputs: pH, dissolved oxygen, conductivity, and temperature (with optional YSI 600 sonde); pH and temperature (with optional Isco 201 Parameter Module); or dissolved oxygen and temperature (with optional Isco 270 Parameter Module)
Sampler Activation Conditions: Enabled, disabled, AND and OR combinations of any two of level, flow rate, rainfall, pH, DO, conductivity, and temperature
Sampler Pacing Output: 12V pulse
Sampler Input: Event mark, bottle number

Printer

Recording Modes: Up to 3 graphs of level, flow rate, pH, DO, conductivity, and temperature vs time; includes totalized flow. Rainfall and sampler events (time and bottle number) are also recorded
Speed: Off, 0.5, 1, 2, 4 in/hr (1.25, 2.5, 5, 10 cm/hr)
Recording Span: User selectable with multiple over-ranges
Resolution: 1/240 of recording span
Reports Printed: Flow meter program, 2 independent time interval reports, flow meter history, sampler history
Interval Report Contents: Site number; time interval; total flow; minimum, maximum, and average flow rate, level, pH, DO, conductivity, and temperature, and time of occurrence; interval flow; total rainfall; number of samples, flow meter history and sampler history
Character Size (HxW): 0.09 x 0.07 in (2.4 x 1.7 mm)
Paper: 4.5 in. wide x 65 ft. (11.4 cm x 19.8 m), plain white paper, replaceable roll
Ribbon: 19.7 ft. (6.0 m) black nylon, replaceable

Data Storage Memory

Capacity: 80,000 bytes (approx. 40,000 readings) divided into a maximum of 12 memory partitions. Equal to 100 days of level, rainfall, pH, DO, conductivity, and temperature readings at 15 minute intervals, plus 3,000 sample events. Optional expansion to 473,000 bytes (approx 236,500 readings)
Setup and Data Retrieval: IBM PC or compatible computer with Isco Flowlink 4 for Windows
Communication: Direct connection, optional internal 2400 baud telephone modem with voice messaging
Data Retrieval (optional): Isco 581 Rapid Transfer Device (RTD)
Voice Messaging (with optional internal modem): Calls up to 5 telephone numbers with programmable delay between calls, activated based on AND and OR combinations telephone of any two of level, flow rate, rainfall, pH, DO, conductivity, and temperature
Analog Outputs: (optional) Up to 3 isolated internal outputs, 0 to 20 mA or 4 to 20 mA, scaleable based on level, flow rate, pH, DO, conductivity, or temperature, into a maximum of 750 ohms each
Relay Outputs: 2 form C relays with field selectable trip points based on flow rate (with optional High/Low Alarm Relays)
Serial Output: Current status and readings, in response to command or automatically at selectable time intervals, ASCII comma separated values at 1200, 2400, 4800, or 9600 baud
Storage Temperature: -40° to 140°F (-40° to 60°C)
Operating Temperature: 0° to 140°F (-18° to 60°C)

Ultrasonic Sensor

Length x diameter: 6.9 x 3.6 in (17.5 x 9.1 cm)
Cable Lengthxdiameter: 25 ft x 0.3 in (7.6 m x 0.8 cm)
Weight (incl cable): 2.6 lbs (1.2 kg)
Enclosure: NEMA 4X, 6; IP67
Frequency: 40 kHz
Range (distance from sensor to liquid): Minimum 2 ft (0.6 m); Maximum 12 ft (3.7 m)
Span: 0 to 10 ft (0 to 3 m)
Blanking Distance: 2 to 12 ft. (0.6 to 3.7 m)

Level Measurement Accuracy - at 22°C (72°F), still air, 40 to 70% humidity. Head change is actual change in vertical distance from ultrasonic sensor to liquid surface)

for head change <1.0 ft (<0.31 m): maximum error is ±0.02 ft. (±0.006 m)
for head change of 1.0 to 10 ft (0.31 to 3.05 m): maximum error is ±0.03 ft. (±0.009 m)
Temperature Coefficient: Maximum error over compensated temperature range (per degree of temperature change) ±0.000047 x D per °F (±0.000085 x D per °C) where D is the distance from the transducer to the liquid surface
Operating Temperature: -22° to 140°F (-30° to 60°C)
Compensated Temperature: -22° to 140°F (-30° to 60°C)
Materials: Sensor housing is Xenoy 6120; Cable jacket is Polyvinyl chloride (PVC)

Back To Top ^


 

 4220 Flow Meter

Submerged probe accuracy unaffected by wind, steam, foam, turbulence or air temperature change. 

The probe on the Isco 4220 uses a differential pressure transducer to measure the depth of the liquid. The probe accurately senses pressure even when covered with silt and sand, and the venting system automatically compensates for changes in atmospheric pressure. This technology provides accurate measurement at sites where wind, steam, foam, turbulence, or air temperature fluctuations exist. 

Isco mounting rings make it easy to install the probe in round pipes and manhole inverts. With the Isco Street Level Installation Tool, you can install your monitoring system from ground level, eliminating the costs and hazards of entering manholes. Most flumes are available with an integral recess for mounting an Isco Submerged Probe.

Standard Features

  • Built-in level-to-flow conversions for most applications. 
  • Choice of standard (10 ft) and extended (30 ft) level measurement range. 
  • Venting system automatically compensates for atmospheric pressure changes 
  • Two-line x 80-character backlit LCD. 
  • Built-in dot matrix printer gives you an accurate, on-site printout 
  • Internal memory stores over 2 months of data. 
  • Easy interfacing for Sampler, water quality sonde, alarm outputs

Applications

  • Pretreatment Compliance 
  • Stormwater Runoff Monitoring 
  • Permit Enforcement 
  • Sewer Flow Monitoring 
  • Combined Sewer Overflow Studies 
  • Wastewater Treatment Plant Operations 
  • Inflow and Infiltration Studies 
  • River and Stream Gauging

Options and Accessories

  • Internal telephone modem 
  • Analog Outputs (up to 3) 
  • Mounting rings and sensor carrier (for installing probe in round pipes from 6 to 15 inches) 
  • Non-resettable totalizer 
  • 674 Rain Gauge 
  • 581 RTD data retrieval device 
  • 201 pH module adds pH and temperature measurement/logging 
  • YSI 600 Multi-Parameter Water Quality Monitor 
  • Suspension equipment (to hang flowmeter in manhole)
 

 

Specifications

Size (H x W x D): 17.0 x 11.5 x 10.5 in. (43 x 29 x 26.7 cm) (without power source)
Weight: 17.3 lbs (7.8 kg) (without power source)
Material: High-impact molded polystyrene structural foam
Enclosure: NEMA 4X (iP65)
Program Memory: Non-volatile, programmable flash. Updateable without opening enclosure.
Display: Backlit LCD, 2-line, 80-character (5.5 mm high x 3.2 mm wide)
Storage Temperature: -40° to 140°F (-40° to 60°C)
Operating Temperature: 0° to 140°F (-18° to 60°C)
Power: 12 to 14V DC, 24 mA average at 12.5V DC

Typical battery life (printer set at 1 in/hr, 1 minute level reading interval)

934 NiCad Battery: 8 to 11 days
946 Lead-Acid Battery: 12 to 16 days
948 Lead-Acid Battery: 21/2 to 3 months

Submerged probe

Dimensions: 9.5 x 0.875 in (24.1 x 2.2 cm)
Cable: Standard range probe - 25 ft x 0.3 in (7.6 m x 0.8 cm);
Level Measurement Method: Submerged pressure transducer mounted in the flow stream
Transducer Type: Differential linear integrated circuit pressure transducer
Operating Temperature: 32° to 160°F (0° to 71°C)
Compensated Temperature: 32° to 100°F (0° to 38°C)
Level Measurement Range: 0.1 to 10 ft (0.03 to 3.05 m)
Maximum allowable level: 20 ft (6.1 m)

Level Measurement Accuracy (at 25°C (77°F) - Max error (±) for indicated level range)

0.1 to 5.0 ft (0.03 to 1.52 m): ±0.01 ft (±0.003 m)
0.1 to 7.0 ft (0.03 to 2.13 m): ±0.03 ft (±0.009 m)
0.1 to 10 ft (0.03 to 3.05 m): ±0.10 ft (±0.03 m)

Temperature Coefficient (Maximum error per degree of temperature change over compensated range)

0.1 to 4.0 ft (0.03 to1.22m): ±0.005ft/°F (±0.0027m/°C)
4.0 to 10 ft (1.22 to 3.05m): ±0.007ft/°F (±0.0038m/°C)

Materials

Submerged probe: Type 316 stainless steel, chlorinated polyvinyl chloride (CPVC)
Cable: Polyvinyl chloride (PVC)

Back To Top ^


 

 4230 Flow Meter

Bubbler level sensing provides the most accurate measurement. 

 

Isco 4230 Bubbler Flow Meters use an internal air compressor to force a metered amount of air through a bubble line submerged in the flow channel. By measuring the pressure needed to force air bubbles out of the line, the flow level is accurately determined. 

Measurement accuracy of the 4230 is not affected by wind, steam, foam or turbulence, nor by suspended solids and rapidly changing head heights that can cause problems for some bubbler flow meters. Because only the bubble tube contacts the flow, corrosive chemicals are not a problem. The 4230 also resists damage by lightning and debris, making it ideal for stormwater applications. 

Automatic Drift Compensation makes Isco bubbler flow meters the most accurate level measurement technology. In standby applications such as stormwater runoff monitoring, Automatic Drift Compensation also allows the 4230 to maintain calibration indefinitely. Automatic bubble line purging prevents clogging, and the meter's internal software senses rapidly rising heads and increases the bubble rate to maintain maximum accuracy.

Standard Features

  • Built-in flow conversions for most applications, including Manning formula, data points, or equation for special situations. 
  • Two-line x 80-character backlit LCD. 
  • Choice of standard (10 ft) and extended (30 ft) level measurement range. 
  • Built-in dot matrix printer gives you an accurate, on-site printout 
  • Internal memory stores over 2 months of flow, rainfall, parameter, and sample data at 15 minute intervals. 
  • Automatic Drift Compensation eliminates effects of transducer drift and allows the 4230 to maintain level calibration indefinitely 
  • Interfacing for Sampler activation, connection to multiparameter water quality sonde, alarm outputs

Applications

  • Portable and fixed-site flow measurement with weirs and flumes 
  • Pretreatment Compliance 
  • Stormwater Runoff Monitoring 
  • Permit Enforcement 
  • Sewer Flow Monitoring 
  • Combined Sewer Overflow Studies 
  • Wastewater Treatment Plant Operations 
  • Inflow and Infiltration Studies 
  • River and Stream Gauging

Options and Accessories

  • Optional telephone modem - provides remote data retrieval, voice messaging, and dial-out alarm conditions 
  • Analog Outputs - up to 3 isolated internal 4-20 mA outputs 
  • Metering inserts for street level installation of bubble line in round pipes from 6 to 12 inches in diameter 
  • Non-resettable totalizer 
  • 674 Rain Gauge 
  • 581 RTD data retrieval device downloads up to 20 meters 
  • 201 pH module adds pH and temperature measurement/logging 
  • YSI 600 Multi-Parameter Water Quality Monitor 
  • Suspension equipment (to hang flowmeter in manhole)
 

 

Specifications

4230 Bubbler Flow Meter

Size (H x W x D): 17.0 x 11.5 x 10.5 in. (43 x 29 x 26.7 cm) (without power source)
Weight: 17.3 lbs (7.8 kg) (without power source)
Material: High-impact molded polystyrene structural foam
Enclosure: NEMA 4X (iP65)
Power: 12 to 14V DC, 16 mA average at 12.5V DC

Typical Battery Life (printer set at 1 in./hr (2.5 cm/hr), 1 bubble per second, 15 minute purge, and continuous level reading interval)

934 Nickel-Cadmium Battery: 7 to 10 days
946 Lead-Acid Battery: 10 to 15 days
948 Lead-Acid Battery: 2 to 3 months
Program Memory: Non-volatile, programmable flash. Updateable without opening enclosure.
Display: Backlit LCD, 2-line, 80-character (5.5 mm high x 3.2 mm wide)

Level-to-Flow Rate Conversions

Weirs: V-notch, rectangular with and without end contractions, Cipolletti
Flumes: Parshall, Palmer-Bowlus, Leopold-Lagco,Trapezoidal, H, HS, HL
Manning Formula: Round, U-channel, rectangular, trapezoidal Data Points Four sets of 50 level-flow rate points Equation Two-term polynomial

Totalizers

LCD: 9-digit, floating decimal point, resettable
Mechanical (optional): 7-digit, non-resettable

Inputs and outputs

Rain gauge input: Contact closure, normally open. Resolution 0.01 or 0.004 in ( 0.25 or 0.1 mm)
Parameter Inputs: pH, dissolved oxygen, conductivity, and temperature (with optional YSI 600 sonde); pH and temperature (with optional Isco 201 Parameter Module); or dissolved oxygen and temperature (with optional Isco 270 Parameter Module)
Sampler activation conditions: Enabled, disabled, AND and OR combinations of any two of level, flow rate, rainfall, pH, DO, conductivity, and temperature
Sampler pacing output: 12V pulse
Sampler input: Event mark, bottle number

Printer

Recording modes: Up to 3 graphs of level, flow rate, pH, DO, conductivity, and temperature vs time; includes totalized flow. Rainfall and sampler events (time and bottle number) are also recorded
Speed: Off, 0.5, 1, 2, 4 in/hr (1.25, 2.5, 5, 10 cm/hr)
Recording Span: User selectable with multiple over-ranges
Resolution: 1/240 of recording span
Reports Printed: Flow meter program, 2 independent time interval reports, flow meter history, sampler history
Interval Report Contents: Site number; time interval; total flow; minimum, maximum, and average flow rate, level, pH, DO, conductivity, and temperature, and time of occurrence; interval flow; total rainfall; number of samples, flow meter history and sampler history
Character Size (HxW): 0.09 x 0.07 in (2.4 x 1.7 mm)
Paper: 4.5 in. wide x 65 ft. (11.4 cm x 19.8 m), plain white paper, replaceable roll
Ribbon: 19.7 ft. (6.0 m) black nylon, replaceable

Data Storage Memory

Capacity: 80,000 bytes (approx. 40,000 readings) divided into a maximum of 12 memory partitions. Equal to 100 days of level, rainfall, pH, DO, conductivity, and temperature readings at 15 minute intervals, plus 3,000 sample events. Optional expansion to 473,000 bytes (approx 236,500 readings)
Setup and Data Retrieval: Windows-compatible computer with Isco Flowlink Software
Communication: Direct connection, optional internal 2400 baud telephone modem with voice messaging, or optional internal short haul modem
Data Retrieval (optional): Isco 581 Rapid Transfer Device (RTD)
Voice Messaging (with optional internal modem): Calls up to 5 telephone numbers with programmable delay between calls, activated based on AND and OR combinations telephone of any two of level, flow rate, rainfall, pH, DO, conductivity, and temperature
Analog Outputs: (optional) Up to 3 isolated internal outputs, 0 to 20 mA or 4 to 20 mA, scaleable based on level, flow rate, pH, DO, conductivity, or temperature, into a maximum of 750 ohms each
Relay Outputs: 2 form C relays with field selectable trip points based on flow rate (with optional High/Low Alarm Relays)
Serial Output: Current status and readings, in response to command or automatically at selectable time intervals, ASCII comma separated values at 1200, 2400, 4800, or 9600 baud
Storage Temperature: -40° to 140°F (-40° to 60°C)
Operating Temperature: 0° to 140°F (-18° to 60°C)

Bubbler

Range: 0.1 to 10 ft (0.03 to 3.05 m)

Level Measurement Accuracy (Non-linearity, repeatability, and hysteresis at 25°C (77°F). Max error (±) for indicated level range.

0.1 to 5.0 ft (0.03 to 1.52 m): ±0.005 ft (±0.002 m)
0.1 to 7.0 ft (0.03 to 2.13 m): ±0.01 ft (±0.003 m)
0.1 to 10 ft (0.03 to 3.05 m): ±0.035 ft (±0.011 m)

Temperature Coefficient (Maximum error (±) per degree of temperature change over compensated range)

For level in feet: ±0.0003 x level x temperature change from 72°F
For level in meters: ±0.0009 x level x temperature change from 22°C
Automatic Drift Correction: After a 5 minute warm-up period, zero level is corrected to ±0.002 ft. (±0.0006 m) at intervals between 2 and 15 minutes
Long-Term Level Calibration Change: Typically 0.5% of reading per year
Ambient Operating Temperature Range: 0° to 140°F (-18° to 60°C)
Compensated Temperature Range: 32° to 140°F (0° to 60°C)

Back To Top ^


 

 4250 Flow Meter

Area Velocity - no weir or flume needed! Handles submerged, surcharged, and reverse flow. 

 

The sensor on the Isco 4250 uses patented Doppler technology to directly measure average velocity in the flow stream. An integral pressure transducer measures liquid depth to determine flow area. The 4250 then calculates flow rate by multiplying the area of the flow stream by its average velocity. 

The 4250 gives you greater accuracy in applications where weirs or flumes are not practical, or where submerged, full pipe, surcharged and reverse flow conditions may occur. With area velocity you don’t have to estimate the slope and roughness of the channel. And Isco’s exclusive 500 kHz Doppler penetrates farther into deep flow streams than 1 MHz systems, whose shorter wavelength can cause them to give “nearsighted” velocity measurement in typical wastewater applications. The Doppler system continuously profiles the flow stream, eliminating profiling and calibration required by electromagnetic systems.

Standard Features

  • 4200 Series 
    - Built-in flow conversions for most applications, including Manning formula, data points, or equation for special situations. 
    - Set up with or without a computer. All setup functions can be done either via onboard keypad and two-line x 80-character backlit LCD, or by connection to PC with Flowlink software. 
    - Built-in dot matrix printer gives you an accurate, on-site printout 
    - Internal memory stores over 2 months of flow, rainfall, parameter, and sample data at 15 minute intervals. 
    - Outputs for Sampler activation, alarm outputs 
    - Inputs for connection to 674 Rain Gauge and multiparameter water quality sonde, 
  • 4250 Area Velocity 
    - Sealed Area-Velocity sensor resists fouling by oil and grease. Streamlined shape sheds debris. 
    - Choice of standard (10 ft) and extended (30 ft) level measurement range.

Applications

  • Accurate open channel flow measurement without a weir or flume 
  • Pretreatment Compliance 
  • Stormwater Runoff Monitoring 
  • Permit Enforcement 
  • Sewer Flow Monitoring 
  • Combined Sewer Overflow Studies 
  • Inflow and Infiltration Studies 
  • River and Stream Gauging

Options and Accessories

  • Choice of Standard and Low Profile Area Velocity Sensors. 
    - Standard Sensor is recommended for larger pipes and turbid flows with high concentrations of suspended solids and entrained air. 
    - Low Profile Sensor is recommended for shallows flows, typically down to 1" (25 mm). 
  • Optional telephone modem - provides remote data retrieval, voice messaging, and dial-out alarm conditions 
  • Analog Outputs - up to 3 isolated internal 4-20 mA outputs 
  • Mounting rings for installation of probe in round pipes from 6 to 15 inches in diameter 
  • Non-resettable totalizer 
  • 674 Rain Gauge 
  • 581 RTD data retrieval device downloads up to 20 meters 
  • 201 pH module adds pH and temperature measurement/logging 
  • YSI 600 Multi-Parameter Water Quality Monitor 
  • Suspension equipment (to hang flowmeter in manhole)
 

 

Specifications

Size (H x W x D): 17.0 x 11.5 x 10.5 in. (43 x 29 x 26.7 cm) (without power source)
Weight: 17.3 lbs (7.8 kg) (without power source)
Material: High-impact molded polystyrene structural foam
Enclosure: NEMA 4X (iP65)
Power: 12 to 14V DC, 14 mA average at 12.5V DC

Typical Battery Life (printer set at 1 in/hr, 1 minute level reading interval, 5 minute velocity reading interval)

934 Nickel-Cadmium Battery: 8 to 11 days
946 Lead-Acid Battery: 12 to 16 days
948 Lead-Acid Battery: 2½ to 3 months
Program Memory: Non-volatile, programmable flash. Updateable without opening enclosure.
Display: Backlit LCD, 2-line, 80-character (5.5 mm high x 3.2 mm wide)

Level-to-Area Conversions

Channel shapes: Round, U-shaped, rectangular, trapezoidal
Data points: Four sets of 50 level-area points

Level-to-Flow Rate Conversions

Weirs: V-notch, rectangular, Cipolletti
Flumes: Parshall, Palmer-Bowlus, Leopold-Lagco,Trapezoidal, H, HS, HL
Manning Formula: Round, U-channel, rectangular, trapezoidal
Data Points: Four sets of 50 level-flow rate points
Equation: Two-term polynomial

Totalizers

LCD: Total, forward, and reverse flow; 9 digits each, floating decimal point, resettable
Mechanical (optional): Total flow, 7 digits, non-resettable

Area Velocity Sensor (See separate specifications for low-profile sensor)

Size (LxWxH): 6.6 x 1.6 x 1.2 inches (16.8 x 4.1 x 3.0 cm)
Weight, incl. cable: 2.1 lbs (0.96 kg) for standard probe with 25 foot cable; 3.9 lbs (1.8 kg) for extended range probe with 50 ft cable.
Ambient Operating Temperature Range: 0° to 140°F (-18° to 60°C)
Compensated Temperature Range: 32° to 140°F (0° to 60°C)
Materials: Polybutadiene-based polyurethane, stainless steel; PVC and CPVC cable

Velocity Measurement

Method: Doppler Ultrasonic, 500 kHz
Velocity range: -5 to +20 ft/s (-1.5 to 6.1 m/s)

Level Measurement

Method: Submerged pressure transducer
Standard range probe: measurement range 0.05 to 10 ft (0.015 to 3.05 m); max level 20 ft (6.1 m)
Extended range probe: measurement range 0.05 to 30 ft (0.015 to 9.14 m); max level 40 ft (12.2 m)

Standard probe accuracy (Non-linearity, repeatability, and hysteresis at 25°C (77°F). Max error for indicated level range.

0.033 to 5.0 ft (0.01 to 1.52 m): ±0.008 ft/ft (±0.008 m/m)
>5.0 ft (>1.52 m): ±0.012 ft/ft (±0.012 m/m)

Extended probe accuracy (Non-linearity, repeatability, and hysteresis at 25°C (77°F). Max error for indicated level range.

0.05 to 15 ft (0.015 to 4.57 m): ±0.03 ft (±0.009 m)
0.05 to 21 ft (0.015 to 6.4 m): ±0.09 ft (±0.027 m)
0.05 to 30 ft (0.015 to 9.14 m): ±0.3 ft (±0.09 m)

Back To Top ^