Isco’s 2100 Series offers flexible, modular design and easy configuration for a wide range of networked open-channel flow monitoring applications, including Inflow and Infiltration studies, cMOM and AMP data collection, and river monitoring.
Compact, stackable, NEMA 4x, 6P (IP68) modules snap together to provide the capabilities needed for practically any site and monitoring requirement.
2100 Series modularity with advanced non-contacting laser Doppler technology
Continuous wave Doppler flow meter is ideal for portable flow surveys and permanent installations.
For redundant level measurement with 2150, or standalone ultrasonic level/flow measurement
Remote data retrieval via spread spectrum radio - eliminates repeated manhole entry
Avoid the complexity and risks of damage in field use of laptop PCs
Wireless flow data retrieval and alarms via CDMA; 1xRTT compatible
Flow data retrieval and alarms via land-line phone connection
Retrieve flow data and receive alarms via your GSM wireless service; GPRS compatible
A powerful solution for flow and parameter data interchange needs
CSA approved for Class 1, Division 1 environments
Flexible installation and data communication for Class 1, Division 1 environments
Easy interfacing from 2100 Series to SCADA/DCS
Area Velocity meter - Baseefa approved as ATEX Group II, Category 1G
2160 LaserFlow™ Area Velocity Module
2100 Series modularity with advanced non-contacting laser Doppler technology
The 2160 LaserFlow Module uses non-contact Laser Doppler Velocity technology and non-contact Ultrasonic Level technology to remotely measure open-channel flow. The sensor has advanced technology to measure velocity with a laser beam at single or multiple points below the surface of the wastewater stream. Standard Features
Applications
Options and Accessories
|
Specifications
2160 LaserFlow™ Module |
|
Size (HxWxD): | 2.9 x 11.3 x 7.5 in. (7.4 x 28.7 x 19.1 cm) |
Weight: | 2.3 lbs 1.0 kg 2160 Module; 6.0 lbs 2.7 kg 2160 Module with 2191 Battery Module |
Material: | High-impact polystyrene, Stainless steel |
Enclosure: | IP 68 (self-certified) |
Power: | 7.0 to 16.6 VDC, Typical operating current 25 mA at 12 VDC Nominal, 1.0mA standby. |
Typical Battery Life: | 12 weeks at 15 minute data storage interval; 7 weeks at 5 minute data storage interval (2160 module, 2191 Battery Module with Eveready Energizer model 529 alkaline lantern batteries, and LaserFlow sensor) |
Program Memory: | Non-volatile, programmable flash; can be updated using PC without opening enclosure; retains user program after updating |
Number of Modules: | Up to 4, field interchangeable |
Maximum Distance between Remote Modules: | 3300 ft, 1000 m |
Wiring between Modules: | Twisted pair for communication, pair for power, gauge dependent on distance |
Total Flow Calculations: | Up to 2 independent level-to-area and/or level-to-flow rate conversions, net, positive or negative, based on either flow rate conversion |
Level-to-Area Conversions: | Round, U-shaped, rectangular, trapezoidal, elliptical, channel shapes with silt correction; data Points Up to 50 level-area pairs |
Level-to-Flow Rate Conversions: | Weirs- V-notch, rectangular, Cipolletti, Isco Flow Metering Inserts, Thel-Mar; Flumes- Parshall, Palmer-Bowlus, Leopold-Lagco, trapezoidal, H, HS, HL; Manning Formula- Round, U-shaped, rectangular, trapezoidal; data Points Up to 50 level-flow rate points; equation- two-term polynomial |
Data Storage Memory: | Non-volatile flash; retains stored data during program updates |
Data Storage Capacity: | 798,000 bytes (up to 158,000 readings, equal to over 270 days of level, velocity, flow rate, ultrasonic signal, Doppler frequency, and input voltage readings at 15 minute intervals). |
Data Types: | Flow Rate, Flow Rate 2, Total Flow, Input Voltage; LaserFlow Level, Distance, Velocity; Optional 350 AV Level, Temperature, Velocity |
Storage Mode: | Rollover with variable rate data storage |
Storage Interval: | 15 or 30 seconds; 1, 2, 5, 15, or 30 minutes; or 1, 2, 4, 12, or 24 hours |
Bytes per reading: | 5 |
Setup and Data Retrieval: | Serial connection to IBM PC or compatible computer with Isco Flowlink software |
Baud Rate: | 38,400 |
Operating and Storage Temperature range: | -40° to 140°F, -40° to 60°C |
Continuous wave Doppler flow meter is ideal for portable flow surveys and permanent installations.
The 2150 Flow Module uses continuous wave Doppler technology to measure mean velocity. The sensor transmits a continuous ultrasonic wave, then measures the frequency shift of returned echoes reflected by air bubbles or particles in the flow. Standard Features
Applications
Options and Accessories
|
Specifications
2150 Flow Module |
|
Size (HxWxD): | 2.9 x 11.3 x 7.5 in (74 x 287 x 191 mm) |
Weight: | 2.0 lb (0.9 kg) |
Materials of construction: | High-impact polystyrene, stainless steel |
Enclosure (self-certified): | NEMA 4X, 6P (IP68) |
Temperature Range: | -40° to 140° F (-40° to 60° C) operating and storage |
Power Required: | 12 VDC nominal (7.0 to 16.6 VDC), 100 mA typical, 1 mA standby |
Power Source: | Typically, an Isco 2191 Battery Module, containing 2 alkaline or 2 rechargeable lead-acid batteries. (Other power options are available; ask for details.) |
Typical Battery Life: | (using 15-minute data storage interval) Energizer® Model 529 alkaline - 15 months; Isco rechargeable lead-acid - 2.5 months |
Program Memory: | Non-volatile programmable flash; can be updated using PC without opening enclosure; retains user program after updating. |
Built-in Conversions |
|
Flow Rate Conversions: | Up to 2 independent level-to-area conversions and/or level-to-flow rate conversions. |
Level-to-Area Conversions: | Channel Shapes - round, U-shaped, rectangular, trapezoidal, elliptical, with silt correction; Data Points - Up to 50 level-area points. |
Level-to-Flow Conversions: | Most common weirs and flumes; Manning Formula; Data Points (up to 50 level-flow points); 2-term polynomial equation |
Total Flow Calculations: | Up to 2 independent, net, positive or negative, based on either flow rate conversion |
Data Handling and Communications |
|
Data Storage: | Non-volatile flash; retains stored data during program updates. Capacity 395,000 bytes (up to 79,000 readings, equal to over 270 days of level and velocity readings at 15-minute intervals, plus total flow and input voltage readings at 24-hour intervals) |
Data Types: | Level, velocity, flow rate 1, flow rate 2, total flow 1, total flow 2, input voltage, temperature |
Storage Mode: | Rollover; 5 bytes per reading. |
Storage Interval: | 15 or 30 seconds; 1, 2, 5, 15, or 30 minutes; or 1, 2, 4, 12, or 24 hours; Storage rate variable based on level, velocity, flow rate, total flow, or input voltage |
Data Retrieval: | Serial connection to PC or optional 2101 Field Wizard module; optional modules for spread spectrum radio; land-line or cellular modem; 1xRTT. Modbus and 4-20 mA analog available. |
Software: | Isco Flowlink for setup, data retrieval, editing, analysis, and reporting |
Multi-module networking: | Up to four 2100 Series Flow Modules, stacked and/or remotely connected. Max distance between modules 3300 ft (1000 m). |
Serial Communication Speed: | 38,400 bps |
2150 Area Velocity Sensor |
|
Size (HxWxD): | 0.75 x 1.3 x 6.0 in (19 x 33 x 152 mm) |
Cable (Length x Diameter): | 33 ft x 0.37 in (10 m x 9 mm) standard. Custom lengths available on request. |
Weight (including cable): | 2.2 lbs (1 kg) |
Materials of construction: | Sensor - Epoxy, chlorinated polyvinyl chloride (CPVC), stainless steel; Cable - Polyvinyl chloride (PVC), chlorinated polyvinyl chloride (CPVC) |
Operating Temperature: | 32° to 140° F (0° to 60° C) |
Level Measurement |
|
Method: | Submerged pressure transducer mounted in the flow stream |
Transducer Type: | Differential linear integrated circuit pressure transducer |
Range: | (standard) 0.033 to 10 ft (0.010 to 3.05 m); (optional) up to 30 ft (9.15 m). |
Maximum Allowable Level: | 34 ft (10.5 m) |
Accuracy: | ±0.01 ft from 0.033 to 10 ft, (±0.003 m from 0.01 to 3.05 m) |
Long-Term Stability: | ±0.023 ft/yr (±0.007 m/yr) |
Compensated Range: | 32° to 122°F (0° to 50°C) |
Velocity Measurement |
|
Method: | Doppler ultrasonic, frequency 500 kHz |
Typical Minimum Depth: | 0.08 ft (25 mm) |
Range: | -5 to +20 ft/s (-1.5 to +6.1 m/s) |
Accuracy: | (in water with uniform velocity profile, speed of sound = 4850 ft/s, for indicated velocity range); ±0.1 ft/s from -5 to 5 ft/s (±0.03 m/s from -1.5 to +1.5 m/s); ±2% of reading from 5 to 20 ft/s (1.5 to 6.1 m/s) |
Temperature Measurement |
|
Accuracy: | ±3.6° F (±2° C) |
2191 Battery Module |
|
Size (HxWxD): | 6.0 x 9.6 x 7.6 in (152 x 244 x 193 mm) |
Weight (without batteries): | 3.2 lb (1.4 kg) |
Materials of construction: | High-impact polystyrene, stainless steel |
Enclosure (self certified): | NEMA 4X, 6P, (IP68) |
Batteries: | Two 6-volt Energizer Model 529* alkaline (25 Ahrs capacity) or Isco Rechargeable Lead-acid (5 Ahrs capacity) recommended. *Note - Energizer 529 ER does not give specified life. |
For redundant level measurement with 2150, or standalone ultrasonic level/flow measurement
The 2110 Ultrasonic Module provides accurate non-contact liquid level measurement, using built-in software to calculate flow in weirs, flumes and streams. When used in conjunction with Isco’s Flowlink® data handling software, that information can be managed and used in a wide variety of ways. Standard Features
Applications
Options and Accessories
|
Specifications
2110 Ultrasonic Module |
|
Size (H x W x D): | 2.9 x 11.3 x 7.5 in. (7.4 x 28.7 x 19.1 cm) |
Weight: | 2.4 lbs. (1.08 kg) |
Material: | High-impact molded polystyrene, stainless steel |
Enclosure (self-certified): | NEMA 4X, 6P (IP68) |
Power Required: | 7 to 15V DC, typical operating current 60 mA at 12V DC, 0.3 mA standby |
Typical Battery Life: | *15 months (Level, temperature, and flow rate at 15-minute intervals; input voltage and total flow at 24 hour storage interval.) *Note: Using Energizer 529 alkaline batteries, discharged to a no load voltage of 4.2V DC per battery or 8.4V DC combined from the 2191 Battery Module. |
Program Memory: | Non-volatile, programmable flash; can be updated using PC without opening enclosure;retains user program after updating |
Number of modules connected together: | Up to 4, field interchangeable |
Maximum distance between modules: | 3300 ft. (1000 m) |
Wiring between remote modules: | Twisted pair for communication, pair for power, gauge dependent on distance |
Level-to-Flow Rate Conversions |
|
Weirs: | V-notch, rectangular, Cipolletti, Isco Flow Metering Inserts, Thel-Mar |
Flumes: | Parshall, Palmer-Bowlus, Leopold-Lagco, trapezoidal, H, HS, HL |
Manning Formula: | Round, U-shaped, rectangular, trapezoidal |
Data Points: | Up to 50 level-flow rate points |
Equation: | 2-term polynomial |
Total Flow Calculations: | 1 independent, net positive or net negative, based on flow rate conversion |
Data Storage Memory: | Non-volatile flash; retains stored data during program updates |
Capacity: | 395,000 bytes (up to 79,000 readings, equal to over 270 days of level readings at 15 minute intervals, plus total flow and input voltage readings at 24 hour intervals) |
Data Types: | Level, flow rate, total flow, temperature, input voltage |
Storage Mode: | Rollover with variable rate data storage based on level, flow rate, total flow, or input voltage |
Storage Interval: | 15 or 30 seconds; 1, 2, 5, 15, or 30 minutes; or 1, 2, 4, 12, or 24 hours |
Bytes Per Reading: | 5 |
Setup and Data Retrieval: | Serial connection to IBM PC or compatible computer with Isco Flowlink Software (Version 5.1 or newer recommended) |
Baud Rate: | 38,400 |
Operating temperature: | 0° to 140°F (-18° to 60°C) |
Storage temperature: | -40° to 140°F (-40° to 60°C) |
Ultrasonic Sensor |
|
Enclosure: | NEMA 4X 6P (IP68) |
Length x diameter: | 3.08 x 1.9 in (7.8 x 4.8 cm) |
Cable: | 32.8 ft x 0.3 in (10 m x 0.8 cm) |
Weight (incl cable): | 2.0 lbs (0.9 kg) |
Level Measurement (@ 20-25°C, 30-70% RH, stable, non-stratified air) |
|
Frequency: | 150 KHz, 95KHz |
Cone Angle: | ±8° |
Range: | *150 kHz - 4 to 72 in (0.1 to 1.8 m), 95 kHz - 12 to 144 in (0.3 to 3.6 m). *Note: Zero deadband possible for 150 kHz sensor only, when installed with horizontal mounting bracket. Minimum range specifications not guaranteed at maximum operating temperature. |
Accuracy: | The greater of ±0.013 ft. (3.96 mm) or ±0.0084 ft. (2.56 mm) per foot (0.305 m) from calibration point |
Typical Temperature error: | ± the sum of 0.0042 ft. + 0.00012 ft. per degree from 68°F |
2191 Battery Module |
|
Size (H x W x D): | 6.0 x 9.6 x 7.6 in. (15.2 x 24.4 x 19.3 cm) |
Weight (without batteries): | 3.2 lbs. (1.4 kg) |
Material: | High-impact molded polystyrene |
Enclosure (self-certified): | NEMA 4X, 6P (IP68) |
Batteries: | 6V alkaline lantern or lead-acid lantern, quantity 2 |
Capacity: | 25 Ahrs |
Remote data retrieval via spread spectrum radio - eliminates repeated manhole entry
The 2102 Wireless Module reduces the need for confined space entry in sewer flow studies by providing remote data retrieval from monitoring instruments. Simply clip the 2102 onto one or more 2100 Series flow modules to form a complete, integrated system for acquiring and communicating open channel flow data. The 2102 uses spread-spectrum digital radio for direct, reliable, two-way communication. You can retrieve data from the safety and comfort of your vehicle by simply returning to within range of the monitoring site and interrogating the instruments via a 2102 connected to your laptop computer (running Flowlink software). A single worker can safely and easily perform monitoring tasks that may otherwise require a hazardous entry crew of three or more. The 2102 can also be interfaced with Isco 6700 Samplers, 4200 Series Flowmeters, and 4100 Series Flow Loggers, providing great versatility for labor saving “drive-up data retrieval” in I&I, CSO, SSO, stormwater, and other projects. The 2102 also avoids the monthly expense of using cellular phones and the hassles of conventional radio technology. NOTE: 2102 Modules are available for use in the USA and Canada ONLY. Standard Features
Applications
Options and Accessories
|
Specifications
2102 Wireless Module |
|
Size (HxWxD): | 2.2 x 11.3 x 7.5 in. (5.4 x 28.7 x 19.1 cm) |
Weight: | 2 lbs (0.9 kg) |
Material: | High-impact polystyrene |
Enclosure: | NEMA 4X, 6P and IP68 (connectors capped) |
Operating Temperature: | -0°F to 140°F (-18°C to 60°C) |
Storage Temperature: | -40°F to 140°F (-40°C to 60°C) |
Power |
|
Voltage: | 10 to 16.6V DC (12V DC nominal) |
Current: | <1 mA standby, 300 mA maximum, 5 mA average at 4 minute power cycle |
Typical battery life: | 50 days (with 2 alkaline batteries) |
Transmitter |
|
Frequency: | 902 to 928 MHz Spread Spectrum |
Output power: | 1 Watt |
Typical range: | line of sight - 0.5 miles (0.8 km); from inside manhole - 100 ft (30 m) |
Modulation, GFSK: | 120 kBs - 170 kBs |
Occupied bandwidth: | 230 kHz |
Receiver |
|
Sensitivity: | 108dBm at 10-6 raw BER (bit error rate) |
Selectivity: | 40 dB at fc ± 230 kHz; 60 dB at fc ± 460 kHz |
Data Transmission |
|
Carrier Detect Cycle: | 4 minutes |
Average connect time: | 2 minutes |
Error Detection: | 32 Bit CRC, resend on error |
Data Encryption: | Substitution, dynamic key |
Link Throughput: | 115 kbps |
FCC Identifier: | KNY-205-108213 |
DOC (Canada) Identifier: | 2329 102 336A |
Software/setup: | Via serial connection to computer with Isco Flowlink Software (version 4.11 or above) |
Avoid the complexity and risks of damage in field use of laptop PCs
The 2101 Field Wizard module provides users of our 2100 Series open channel flow monitors with a durable instrument to retrieve and transfer stored data. Unlike vulnerable laptop PCs, the Field Wizard is extremely rugged and is built to survive the hazards of field use. The Field Wizard can interrogate a stack containing as many as four of Isco’s 2100 Series Flow Modules at once. It can download and store more than 14 days worth of data from as many as 20 individual 2100 Series Flow Modules. In addition, Field Wizard allows you to adjust 2100 Series Flow Module level settings. For on-site display, you can clip the Field Wizard directly to a stack of 2100 Series Flow Modules, either temporarily or permanently. A 10 ft module extension cable is also included, allowing the Field Wizard to be hand-held at a comfortable distance from the installed equipment. Data collected from multiple sites can be transferred directly to a PC running Isco Flowlink® 4 Software, through an optional connecting cable. Standard Features
Applications
Options and Accessories
|
Specifications
Size (HxWxD): | 2.2 x 11.3 x 7.5 in. (5.4 x 28.7 x 19.1 cm) |
Weight: | 2 lbs (0.91 kg) |
Material: | Polystyrene |
Enclosure: | NEMA 4X, 6P and IP68 (connectors capped) |
Operating Temperature: | -4°F to 140°F (-20°C to 60°C) |
Storage Temperature: | -40°F to 140°F (-40°C to 60°C) |
Power |
|
Voltage: | 6.6 to 16.6V DC (12V DC nominal) |
Current: | Typical 110 mA @ 12V (LCD backlight off). Minimum 1 mA @ 12V (standby/OFF). Maximum 1.1A @ 12V (LCD backlight on) |
Display |
|
Type: | High contrast LCD. Text - 40 character x 8 lines; Graphics - 240 x 64 pixel. |
Contrast: | Adjustable |
Backlight: | Selectable modes for Always On, Timed, Always Off. |
Display Refresh: | 15 seconds |
Data communication and storage |
|
Memory: | Nonvolatile FLASH, 482,345 readings, 5 bytes per reading. |
Data Capacity: | (2150 Modules downloaded) - Maximum 20 [Limited by number of modules identifiable and displayable on Field Wizard.] Minimum 6 [Limited by 2102 data storage when downloading the maximum data capacity from each module.] |
2150 Modules per site: | Up to 4 |
Data Types: | Parameters compatible with Flowlink® and 2150 (level, velocity, flow, battery voltage, totalized flow) |
Storage Mode: | Slate (stops when full; resets when downloaded to PC) |
Software Compatibility: | Isco Flowlink® Version 4.12 or later; Isco 2150 AV Module Software revision 1.06 or later; 2102 Wireless Module Only in “remote” wireless stations that include one or more 2150 modules [The 2101 does NOT support wireless data retrieval in 2102 wireless base stations.] |
2103Ci CDMA Cellular Modem Module
Wireless flow data retrieval and alarms via CDMA; 1xRTT compatible
This cellular modem module is designed to push Isco 2100 Series flow meter data to a remote Flowlink® database. Data can also be downloaded from the server using an internet connection. The 2103Ci modem module uses Serial Over Internet Protocol (SOIP), so a landline modem is not required. Standard Features
Applications
Options and Accessories
|
Specifications
2103Ci Cellular CDMA Modem Module |
|
Size: | (H x W x D) 2.9 x 10.5 x 7.5 in. (7.4 x 26.7 x 19 cm) |
Weight: | 2.0 lbs. 0.9 kg |
Enclosure: | NEMA 4X, 6P (IP67) |
Material: | High-impact polystyrene |
Power: | Provided by Isco 2191 Battery Module |
Operating temperature: | -4° to 140°F (-20° to 60°C) |
Storage temperature: | -40° to 140°F (-40° to 60°C) |
Setup and data retrieval: | Via PC or compatible computer with Isco Flowlink Software |
2191 Battery Module |
|
Size (H x W x D): | 6.0 x 9.6 x 7.6 in. (15 x 24 x 19 cm) |
Weight (w/o batteries): | 3.2 lbs. 1.4 kg |
Enclosure: | NEMA 4X, 6P (IP67) |
Material: | High-impact polystyrene |
Batteries: | Two 6V alkaline lantern or lead-acid lantern |
Capacity: | Alkaline - 25 Ahrs; Lead Acid - 5 Ahrs |
Flow data retrieval and alarms via land-line phone connection
The 2103 Modem Module eliminates the need for frequent site visits and confined space entry, by automating remote retrieval of data in sewer flow studies. The 2103 uses a land-line modem connection to provide reliable two-way communication between downhole 2100 Series Flow modules and a base computer running Isco Flowlink software. Standard Features
Applications
Options and Accessories
|
Specifications
2103 Modem Module |
|
Size: | (H x W x D) 2.9 x 9.5 x 7.5 in. (7.4 x 24.1 x 19.1 cm) |
Weight: | 2.0 lbs. 0.9 kg |
Enclosure: | NEMA 4X, 6P (IP68) |
Material: | High-impact polystyrene |
Modulation standards: | Bell 103, Bell 212, V.21, V22, V.22bis, V.23, V.32, V.32bis, V.34 |
Error correction standards: | V.42 LAPM, MNP-2, MNP-4, MNP-10 |
Communication speeds: | 0.3, 1.2, 2.4, 4.8, 7.2, 9.6, 12.0, 14.4, 16.8, 19.2, 21.6, 24.0, 26.4, 28.8, 31.2, 33.6 kbps |
Data compression standards: | V.42 bis, MNP-5 |
Power: | 9.0 to 16.6V DC, 0.41 mA standby, 141 mA typical |
Typical Battery Life: | 290 days (with 2 alkaline batteries) |
Operating temperature: | -4° to 140°F (-20° to 60°C) |
Storage temperature: | -40° to 140°F (-40° to 60°C) |
Setup and data retrieval: | Via IBM PC or compatible computer with Isco Flowlink Software |
2191 Battery Module |
|
Size (H x W x D): | 6.0 x 9.6 x 7.6 in. (15.2 x 24.4 x 19.3 cm) |
Weight (w/o batteries): | 3.2 lbs. 1.4 kg |
Enclosure: | NEMA 4X, 6P IP68 |
Material: | High-impact polystyrene |
Batteries: | Two 6V alkaline lantern or lead-acid lantern |
Capacity: | Alkaline - 25 Ahrs; Lead Acid - 5 Ahrs |
2103Gi GSM/GPRS Cellular Modem Module
Retrieve flow data and receive alarms via your GSM wireless service; GPRS compatible
This cellular modem module is designed to push Isco 2100 Series flow meter data to a remote Flowlink® database. It virtually eliminates the need for recurring site visits, time-consuming (and potentially dangerous) confined space entry, as well as costly installation of land lines. Standard Features
Applications
Options and Accessories
|
Specifications
2103Gi GSM/GPRS Modem Module |
|
Size: | (H x W x D) 2.9 x 10.5 x 7.5 in. (7.4 x 26.7 x 19 cm) |
Weight: | 2.0 lbs. 0.9 kg |
Enclosure: | NEMA 4X, 6P (IP67) |
Material: | High-impact polystyrene |
Power: | Provided by Isco 2191 Battery Module |
Operating temperature: | -4° to 140°F (-20° to 60°C) |
Storage temperature: | -40° to 140°F (-40° to 60°C) |
Setup and data retrieval: | Via PC or compatible computer with Isco Flowlink Software |
2191 Battery Module |
|
Size (H x W x D): | 6.0 x 9.6 x 7.6 in. (15 x 24 x 19 cm) |
Weight (w/o batteries): | 3.2 lbs. 1.4 kg |
Enclosure: | NEMA 4X, 6P (IP67) |
Material: | High-impact polystyrene |
Batteries: | Two 6V alkaline lantern or lead-acid lantern |
Capacity: | Alkaline - 25 Ahrs; Lead Acid - 5 Ahrs |
A powerful solution for flow and parameter data interchange needs
The 2105 Interface Module is a powerful solution for environmental monitoring professionals to interface different monitoring and recording instruments. The 2105 will monitor the recorded data and take intelligent actions, such as sampler enabling, pacing, and/or alarm generation, based on user-specified conditions. Its unique flexibility allows connection to several devices at the same time. Isco 2100 Series Flow Modules, Isco’s ADFM pulse Doppler flow meters, 6712 Samplers, 4200 Series Flow Meters, and Isco Rain Gauges are directly compatible. It can also be used with non-Isco instruments that have SDI-12 or Modbus output. Additional input options (4-20 mA, etc.) are possible using readily-available aftermarket converters. An optional built-in cell phone modem allows remote access to data that has been stored within the 2105, and can fed to a central server via the Internet. Isco’s modular design allows the 2105 to be stacked with other 2100 Series flow, communication, interface, or display modules. Standard Features
Applications
Options and Accessories |
Specifications
2105 Network Interface Module |
|
Size (H x W x D): | 2.9 x 11.3 x 7.5 in. (74 x 287 x 191 mm) |
Weight: | 2.0 lbs. 0.9 kg |
Material: | High-impact polystyrene, stainless steel |
Enclosure: | NEMA 4X, 6P IP68 |
Operating temperature: | -4 to 140°F (-20 to 60°C) |
Storage temperature: | -40 to 140°F (-40° to 60C) |
Power Required: | 12 VDC nominal (7.0 to 26 VDC), 100 mA typical, 1 mA standby, 2 A maximum. |
Power Source: | Typically an Isco 2191 Battery Module, containing 2 alkaline or 2 rechargeable lead-acid batteries. (Other power options are available; ask for details.) |
Typical battery life: | Using 15-minute data storage interval— Energizer® Model 529 alkaline, 15 months; Isco rechargeable lead-acid, 2.5 months |
Program Memory: | Non-volatile, programmable flash; can be updated using PC without opening enclosure; retains user program after updating |
Data Handling and Communications |
|
Data Storage: | Non-volatile flash; Retains stored data during program updates; Capacity 798,000 bytes (up to 158,000 readings, equal to over 270 days of rainfall, temperature, conductivity, and pH readings at 15-minute intervals, plus input voltage readings stored at 12-hour intervals) |
Data Types: | Flow Rate, Level, Rainfall, Conductivity, Dissolved Oxygen, Temperature, pH, Percent, Velocity, Volume, Total Dissolved Solids, Salinity, Phosphate, Ammonia, Nitrate, TOC, COD, Total Suspended Solids, Sludge Index, Sludge Volume, SAC, Turbidity, Load, Input Voltage, Wireless Signal, Rainfall Intensity, Specific Conductance, Chloride, Chlorophyll, O.R.P., Ammonium |
Storage Mode: | Rollover; 5 bytes per reading |
Storage Interval: | 15 or 30 seconds; 1, 2, 5, 15, or 30 minutes; or 1, 2, 4, 12, or 24 hours. Storage rate variable based on level, velocity, flow rate, total flow, or input voltage |
Data Retrieval: | Serial connection to PC or optional 2101 Field Wizard module; optional modules for spread spectrum radio; land-line or cellular modem. Modbus and 4-20 mA analog available. |
Software: | Isco Flowlink for setup, data retrieval, editing, analysis, and reporting |
Multi-module networking: | Up to four 2100 Series modules, stacked and/or remotely connected. Maximum distance between modules is 3,300 feet (1000 m) |
Serial Port Communication Speed: | Up to 38,400 bps |
2191 Battery Module |
|
Size (H x W x D): | 6.0 x 9.6 x 7.6 in. (152 x 244 x 193 mm) |
Weight (w/o batteries): | 3.2 lbs. 1.4 kg |
Materials of construction: | High-impact polystyrene, stainless steel |
Enclosure: | NEMA 4X, 6P (IP68) |
Batteries: | Two 6-volt Energizer Model 529* alkaline (26 Ah capacity) or Isco Rechargeable Lead-acid (5 Ah capacity) recommended. *Note - Energizer 529 ER and EN529 do not give specified life. |
2151 Intrinsically Safe Area Velocity Flow Meter
CSA approved for Class 1, Division 1 environments
The 2151 Flow Meter is the intrinsically safe version (CSA approved for Class 1, Div 1 environments) of the 2100 series Area Velocity Flow Meter. To ensure proper application, the 2151 uses a distinctive color, and has connectors that are compatible only with other intrinsically safe 2100 Series components. Highly efficient power management provides battery life up to 8 months. Standard Features
Applications
Options and Accessories
|
Specifications
Isco 2151 Intrinsically Safe Flowmeter |
|
Size (H x W x D): | 8.4 x 11.3 x 7.6 in. (21.3 x 28.7 x 19.3 cm) including battery compartment. |
Weight: | 8.2 lbs. (2.4 kg) |
Material: | High-impact molded polystyrene |
Enclosure: | NEMA 4X, 6P IP68 (self-certified) |
Power: | 6.6 to 16.6V DC, 100 mA typical at 12V DC, 1 mA standby |
Typical battery life, vs. data storage interval (using two 6-volt akaline batteries, Eveready Energizer 529 or EN529) |
|
15 minute interval: | 8 months |
5 minute interval: | 4.5 months |
Program Memory: | Non-volatile, programmable flash; can be updated using PC without opening enclosure; retains user program after updating |
Flow Rate Conversions: | Up to 2 independent level-to-area conversions and/or level-to-flow rate conversions |
Level-to-Area Conversions |
|
Channel Shapes: | Round, U-shaped, rectangular, trapezoidal, elliptical, with silt correction |
Data Points: | Up to 50 level-area points |
Level-to-Flow Rate Conversions |
|
Weirs: | V-notch, rectangular, Cipolletti, Isco Flow Metering Inserts, Thel-Mar; |
Flumes: | Parshall, Palmer-Bowlus, Leopold-Lagco, trapezoidal, H, HS, HL |
Manning Formula: | Round, U-shaped, rectangular, trapezoidal |
Data Points: | Up to 50 level-flow rate points |
Equation: | 2-term polynominal |
Total Flow Calculations: | Up to 2 independent, net, positive or negative, based on either flow rate conversion |
Data Storage Memory: | Non-volatile flash; retains stored data during program updates. Capacity 395,000 bytes (up to 79,000 readings, equal to over 270 days of level and velocity readings at 15 minute intervals, plus total flow and input voltage readings at 24 hour intervals) |
Data Types: | Level, velocity, flow rate 1, flow rate 2, total flow 1, total flow 2, input voltage |
Storage Mode: | Rollover with variable rate data storage based on level, velocity, flow rate 1, flow rate 2, total flow 1, total flow 2, or input voltage |
Storage Interval: | 15 or 30 seconds; 1, 5, 15, or 30 minutes; or 1, 2, 4, 12, or 24 hours. 5 Bytes per reading. |
Setup and Data Retrieval: | Serial connection to IBM PC or compatible computer with Isco Flowlink Software. |
Baud Rate: | 38,400 |
Operating temperature: | 0° to 140°F (-18° to 60°C) |
Storage temperature: | -40° to 140°F (-40° to 60°C) |
Area Velocity Sensor |
|
Size (H x W x L): | 0.75 x 1.31 x 6.00 in. (1.9 x 3.3 x 15.2 cm) |
Cable Length: | 25 ft. (7.6 m) |
Cable Diameter: | 0.37 in. (0.9 cm) |
Weight (including cable): | 2.1 lbs. (0.95 kg) |
Materials: | Sensor - Epoxy, chlorinated polyvinyl chloride (CPVC), stainless steel; Cable - Polyvinyl chloride (PVC), chlorinated polyvinyl chloride (CPVC). |
Level Measurement |
|
Method: | Submerged pressure transducer mounted in the flow stream. |
Transducer Type: | Differential linear integrated circuit pressure transducer |
Range: | 0.033 to 10 ft (0.010 to 3.05 m) |
Maximum Allowable Level: | 20 ft. (6.1 m) |
Accuracy - non-linearity and hysteresis at 77°F (25°C) per foot of change from calibration depth, for indicated level range |
|
0.033 to 5.0 ft (0.03 to 1.52 m): | ±0.008 ft/ft (±0.008 m/m) |
Greater than 5.0 ft (1.52 m): | ±0.012 ft/ft (±0.012 m/m) |
Maximum Long-Term Drift: | 0.033 ft. (0.010 m) |
Temperature Coefficient: | ±0.0035 ft/°F (±0.0019 m/°C) (Max error within compensated range, per degree of change from calibration temperature.) |
Velocity Measurement |
|
Method: | Doppler ultrasonic, Frequency 500 kHz, Transmission Angle 20° from horizontal |
Typical Minimum Depth: | 1 inch (25 mm) |
Range: | -5 to +20 ft/s (-1.5 to +6.1 m/s) |
Accuracy - in water, uniform velocity, speed of sound = 1480 m/s, for indicated velocity range |
|
-5 to +5 ft/s (-1.5 to +1.5 m/s): | ±0.1 ft./s (±0.03 m/s) |
5 to 20 ft/s (1.5 to 6.1 m/s): | ±2% of reading |
Operating Temperature: | 32° to 160°F (0° to 71°C) |
Compensated Range: | 32° to 122°F (0° to 50°C) |
2151P Intrinsically Safe, Permanent Flow System
Flexible installation and data communication for Class 1, Division 1 environments
The 2151P Flow System is similar to the 2151 intrinsically safe Area Velocity Flow Meter, but is designed to operate from AC power for long-term or permanent applications rather than from battery power for shorter-term, portable applications. Like all 2100 Series modules, the 2151P is set up via connection to a computer running Flowlink Software. Standard Features
Applications
Options and Accessories
|
Specifications
Isco 2151P Intrinsically Safe Flow System for Permanent Installations |
|
Size (H x W x D): | 3.75 x 9.5 x 11.0 inches (9.5 x 24.0 x 28.0 cm) |
Weight: | 5.5 lbs (2.5 kg) |
Power: | 12V DC, 100 mA nominal (CSA-approved intrinsically safe) |
Approvals: | CSA Certified for Class I, Div. 1 Group C & D. Temperature Code - T3C at 60° C, ambient. CAN/CSA Standard C22.2 No. 157-92. UL Standard No. 913, Feb. 21, 1994 |
Program Memory: | Non-volatile, programmable flash; can be updated using PC without opening enclosure; retains user program after updating |
Flow Rate Conversions: | Up to 2 independent level-to-area conversions and/or level-to-flow rate conversions |
Level-to-Area Conversions |
|
Channel Shapes: | Round, U-shaped, rectangular, trapezoidal, elliptical, with silt correction |
Data Points: | Up to 50 level-area points |
Level-to-Flow Rate Conversions |
|
Weirs: | V-notch, rectangular, Cipolletti, Isco Flow Metering Inserts, Thel-Mar |
Flumes: | Parshall, Palmer-Bowlus, Leopold-Lagco, trapezoidal, H, HS, HL |
Manning Formula: | Round, U-shaped, rectangular, trapezoidal |
Data Points: | Up to 50 level-flow rate points |
Equation: | 2-term polynominal |
Total Flow Calculations: | Up to 2 independent, net, positive or negative, based on either flow rate conversion |
Data Storage Memory: | Non-volatile flash; retains stored data during program updates. Capacity 395,000 bytes (up to 79,000 readings, equal to over 270 days of level and velocity readings at 15 minute intervals, plus total flow and input voltage readings at 24 hour intervals) |
Data Types: | Level, velocity, flow rate 1, flow rate 2, total flow 1, total flow 2, input voltage |
Storage Mode: | Rollover with variable rate data storage based on level, velocity, flow rate 1, flow rate 2, total flow 1, total flow 2, or input voltage |
Storage Interval: | 15 or 30 seconds; 1, 5, 15, or 30 minutes; or 1, 2, 4, 12, or 24 hours. 5 Bytes per reading. |
Setup and Data Retrieval: | Serial connection to IBM PC or compatible computer with Isco Flowlink Software. |
Baud Rate: | 38,400 |
Operating temperature: | 0° to 140°F (-18° to 60°C) |
Storage temperature: | -40° to 140°F (-40° to 60°C |
Easy interfacing from 2100 Series to SCADA/DCS
The 2108 Output Module provides three independent current outputs for Isco 2100 Series Area Velocity Flow modules; the 2150, 2151, and 2151P. The 2108 is DIN Rail mounted and uses a 7-26V DC power supply. Standard Features
Applications
Options and Accessories
|
Specifications
Isco 2108 Analog Module |
|
Size (H x W x D): | 4.76 x 6.73 x 2.17 in (12.1 x 17.1 x 5.5 cm) |
Weight: | 1.3 pounds (0.6 Kg) |
Case Material: | ABS |
Enclosure Rating: | NEMA 1, IP20 |
Number of Analog Output Channels: | 3 |
Individual Channel Specifications |
|
Output range: | 4 - 20mA* |
Maximum load resistance: | 600 ohms |
Isolation: | Output galvanically isolated from DC power, from the network, and the other outputs. |
Accuracy |
|
Integral Nonlinearity: | ±0.012% max |
Offset ±0.05% max (0mA or 4mA)(Ta = 25°C) |
|
Offset Drift: | 50 ppm/°C max |
Total Output Error: | ±0.15% max (20mA or 24mA)(Ta = 25°C) |
Total Output Error Drift: | 50 ppm/°C max |
PSRR: | 10 µA/V max |
Resolution: | 16 bits, 244 nA, 0.0015% of 16mA span |
Power: | 7.0 to 26.0V DC, 300 mA typical at 12V DC, 280 mA standby |
2150EX Flow Meter for Zone 0 locations
Area Velocity meter - Baseefa approved as ATEX Group II, Category 1G
The 2150EX is an intrinsically safe Area Velocity Flow Meter that is specifically designed and Baseefa-approved for use in Zone 0 and Zone 1 potentially explosive atmospheres under ATEX Directive 94/9/EC. Standard Features
Applications
Options and Accessories
|
Specifications
Isco 2150EX Intrinsically Safe Flow Meter |
|
Size (H x W x D): | 22.6 x 28.0 x 19.3 cm including battery compartment |
Material: | High-impact ABS |
Enclosure: | IP68 (NEMA 4X, 6P, self-certified) |
Power: | 7.0 to 9.0 VDC, 100 mA typical at 8 VDC, 1 mA standby. Power is provided by a 2194EX or 2196EX module. |
Approval: | Baseefa approved as ATEX Group II category 1G equipment, under ATEX Directive 94/9/EC |
Typical Battery Life (estimated): | 2196EX module with permanently installed lead-acid batteries - 6.5 weeks with 2-minute data storage intervals. |
Program Memory: | Non-volatile, programmable flash; can be updated using PC without opening enclosure; retains user program after updating |
Flow Rate Conversions: | Up to 2 independent level-to-area conversions and/or level-to-flow rate conversions |
Level-to-Area Conversions |
|
Channel Shapes: | Round, U-shaped, rectangular, trapezoidal, elliptical, with silt correction |
Data Points: | Up to 50 level-area points |
Level-to-Flow Rate Conversions |
|
Weirs: | V-notch, rectangular, Cipolletti, Isco Flow Metering Inserts, Thel-Mar; |
Flumes: | Parshall, Palmer-Bowlus, Leopold-Lagco, trapezoidal, H, HS, HL |
Manning Formula: | Round, U-shaped, rectangular, trapezoidal |
Data Points: |